Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 16 results
    • https://kb.netapp.com/data-mgmt/AIQUM/AIQUM_Kbs/Cannot_execute_the_setup_login_banner_and_enable_audit_log_actions_in_the_AIQUM_UI
      When trying to setup a login banner or enable audit log from the AIQUM UI the management actions fail suggesting CLI as a workaround Enable auditing on the storage VM using the ONTAP command 'vserver ...When trying to setup a login banner or enable audit log from the AIQUM UI the management actions fail suggesting CLI as a workaround Enable auditing on the storage VM using the ONTAP command 'vserver audit enable-vserver vserver_name! The login banner for the cluster should be enabled to increase security by making access restrictions clear. Configure the cluster login banner using the ONTAP command 'security login banner modify -vserver admin_vserver_name-message message!
    • https://kb.netapp.com/Cloud/Cloud_Volumes_ONTAP/Cloud_Volumes_ONTAP_in_failed_state__Illegal_character_in_header_value
      Applies to Cloud Volumes ONTAP (CVO) Cloud Manager Issue Cloud Volumes ONTAP in failed state Error seen in Cloud Manager GUI: An error occurred while retrieving account subscriptions: Illegal characte...Applies to Cloud Volumes ONTAP (CVO) Cloud Manager Issue Cloud Volumes ONTAP in failed state Error seen in Cloud Manager GUI: An error occurred while retrieving account subscriptions: Illegal character <> in header value An error occurred while retrieving Cloud Provider Accounts: Illegal character <> in header value
    • https://kb.netapp.com/Legacy/OnCommand_Suite/WFA_custom_workflow_failing_with_Connection_timeout_errors
      00000023.000f8a9c 0b8c6630 Fri Nov 08 2019 00:50:56 +05:30 [kern_audit:info:1985] 8503e80000239736 :: :ontapi :: :59089 :: SVM_SAN:wfa_user :: ^M Hourly_CGSnap_52_Friday_November_08_2019_00_50_55^M ^M...00000023.000f8a9c 0b8c6630 Fri Nov 08 2019 00:50:56 +05:30 [kern_audit:info:1985] 8503e80000239736 :: :ontapi :: :59089 :: SVM_SAN:wfa_user :: ^M Hourly_CGSnap_52_Friday_November_08_2019_00_50_55^M ^M N1PL_PD_BTFCU52_Vol07^M N1PL_PD_BTFCU52_Vol08^M N1PL_PD_BTFCU52_Vol11^M N1PL_PD_BTFCU52_Vol12^M N1PL_PD_BTFCU52_Vol15^M N1PL_PD_BTFCU52_Vol16^M Knowledgebase N1PL_PD_BTFCU52_Vol01^M N1PL_PD_BTFCU52_Vol02^M N1PL_PD_BTFCU52_Vol03^M N1PL_PD_BTFCU52_Vol04^M N1PL_PD_BTFCU52_Vol05^M ^M ^M :: Pending 000…
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/FlexArray_back-end_LUNs_show_status_Failed
      FlexArray back-end LUNs show the status as Failed. Node01 failed Error: Takeover failed. Action: Use the "storage failover show-takeover" command to view the cause of takeover failure and the "storage...FlexArray back-end LUNs show the status as Failed. Node01 failed Error: Takeover failed. Action: Use the "storage failover show-takeover" command to view the cause of takeover failure and the "storage failover takeover -ofnode Node Node Status Aggregate Takeover Status To abort the takeover, takeover using the "storage you want to continue the takeover, address the failures and then use the "storage you want to continue with the the failures you can do so by using the "storage failover
    • https://kb.netapp.com/Legacy/OnCommand_Suite/Unable_to_start_DFM_service_with_database_service_failed_error_code_is_100
      Error: Unable to determine if the database needs to be upgraded to the latest file format. Error: The sql service must be running before attempting to start the servlet engine service. Error: The sql ...Error: Unable to determine if the database needs to be upgraded to the latest file format. Error: The sql service must be running before attempting to start the servlet engine service. Error: The sql service must be running before attempting to start the http service. Not attempting to start server because service is started already. dfm service start sql Error: Unable to determine if thedatabase needs to be upgraded to the latest file format.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Element_cluster_upgrade_fails_with__UpgradeError__Staging_storage_node_storage_node_name_failed_on_mNode
      UpgradeError: Staging storage node <storage node name> failed Running check_var_log_disk_space on node Node <node_name> [1]. Running check_var_log_disk_space on node Node <node_name> [2]. Running chec...UpgradeError: Staging storage node <storage node name> failed Running check_var_log_disk_space on node Node <node_name> [1]. Running check_var_log_disk_space on node Node <node_name> [2]. Running check_var_log_disk_space on node Node <node_name> [4]. Running check_root_disk_space on node Node <node_name> [1]. Running check_root_disk_space on node Node <node_name> [2]. Running check_root_disk_space on node Node <node_name> [4]. Running check_upload_speed on node Node <node_name> [1].
    • https://kb.netapp.com/Legacy/OnCommand_Suite/Failed_restoring_WFA_backup_with_error_Failed_restoring_WFA_V4_2_0_0_1
      WFA Backup restore failed with below error Caused by: WFLYEJB0447: Transaction 'Local transaction (delegate=TransactionImple < ac, BasicAction: 0:ffff9f2a64b9:31d0f5b8:605ed82c:9caac status: ActionSta...WFA Backup restore failed with below error Caused by: WFLYEJB0447: Transaction 'Local transaction (delegate=TransactionImple < ac, BasicAction: 0:ffff9f2a64b9:31d0f5b8:605ed82c:9caac status: ActionStatus.ABORTED >, owner=Local transaction context for provider JBoss JTA transaction provider)' was already rolled back
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Chassis_power_supply_is_degraded_Power_Output_has_failed
      EMS reports “CHASSIS POWER SUPPLY NEED TO BE REPLACED: PS 1 and “Chassis power supply 1 is degraded: PSU1 has failed” due to PSU issues.
    • https://kb.netapp.com/data-mgmt/AIQUM/AIQUM_Kbs/Active_IQ_Unified_Manager_is_down
      Applies to Active IQ Unified Manager (AIQUM) 9.6+ OnCommand Unified Manager 6x/7x Issue Unified Manager OVA will not boot. Unified Manager services are down or not responding or wont start
    • https://kb.netapp.com/Legacy/NetApp_HCI/Hardware/Node_DIMM_initialization_fail_error_on_NetApp_H6xx
      Applies to NetApp H610S NetApp H615C Issue ESXi host (H615C) is reachable via ICMP but shows disconnected from vCenter DIMM cannot be initialized successfully, and below IPMI events output repeatedly:...Applies to NetApp H610S NetApp H615C Issue ESXi host (H615C) is reachable via ICMP but shows disconnected from vCenter DIMM cannot be initialized successfully, and below IPMI events output repeatedly: 135 May/19/2020 08:18:10 [Warning] [POST Error] [BIOS POST Progress] 0xA258 : DIMM initialization fail. (CPU1_D0) - Asserted <<<
    • https://kb.netapp.com/hybrid/StorageGRID/Maintenance/Storage_GRID_node_and_or_grid_node_services_have_failed
      Applies to NetApp StorageGRID Issue Multiple storage nodes have been down for a longer period of time. When viewing /var/local/log/servermanager.log on any storage node, it reports: Cassandra not star...Applies to NetApp StorageGRID Issue Multiple storage nodes have been down for a longer period of time. When viewing /var/local/log/servermanager.log on any storage node, it reports: Cassandra not started because it has been offline for longer than its 15 day grace period – rebuild cassandra