    About 5 results
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/Snapcenter_SQL_snapshots_are_not_getting_created_with_the_Label_for_snapvault_transfer
      Applies to SnapCenter plugin for SQL 4.1.x Issue Snapshots are getting created on the primary volume without label, we can notice the below error from the logs. 2020-07-13T02:33:03.2588904-05:00 Criti...Applies to SnapCenter plugin for SQL 4.1.x Issue Snapshots are getting created on the primary volume without label, we can notice the below error from the logs. 2020-07-13T02:33:03.2588904-05:00 Critical SAL PID=[4752] TID=[4892] Error: The credentials for the storage system SVM is not configured. Resolution: Please check if storage system SVM_DR is assigned to the user and is resolvable or add an entry to etc/hosts file.
    • https://kb.netapp.com/Legacy/Snap_Creator/SnapCreator_command_line_fails_to_run_post_upgrade
      While attempting to run the backup using the command post-upgrade of the SnapCreator from 4.3.3P2 or below to 4.3.3P3 or above, the following error will be seen:
    • https://kb.netapp.com/hybrid/StorageGRID/Maintenance/EC_rebalance_job_failed_with_error_Requested_rebalance_operation_failed
      Applies to StorageGRID 11.5.0.8 Issue Rebalancing erasure-coded data failed with error: Requested rebalance operation failed. Internal server error. The server encountered an error and could not compl...Applies to StorageGRID 11.5.0.8 Issue Rebalancing erasure-coded data failed with error: Requested rebalance operation failed. Internal server error. The server encountered an error and could not complete your request. Try again. If the problem persists, contact support. Failed to run command: INVL Error: Cannot start job. A conflicting job is in progress.
    • https://kb.netapp.com/data-mgmt/OTV/SRA_Kbs/SRM_Reprotect_Fails_with_error_XmlValidateException_empty_content_is_not_valid_for_content_model
      SRM has Failed Over from the Protected Site to the Recovery Site. Every attempt to run a Reprotect fails in Step 2 with the following error. Failed to reverse replication for failed over devices. Inte...SRM has Failed Over from the Protected Site to the Recovery Site. Every attempt to run a Reprotect fails in Step 2 with the following error. Failed to reverse replication for failed over devices. Internal error: class Dr::Xml::XmlValidateException "empty content is not valid for content model '(Error|(Success,Warnings) In the SRM log bundle, a log file named vmware-dr-###.log shows the below error --> reason = "class Dr::Xml::XmlValidateException "empty content is not valid for content
    • https://kb.netapp.com/data-mgmt/OTV/VSC_Kbs/Failed_to_Enable_SRA_from_VSC_in_vCenter
      Applies to VSC 9.7P2 vCenter Server 6.5 and later Issue Unable to enable SRA with error: Error updating capabilities, due to internal processing exception: Unable to connect to VMware Profile Driven S...Applies to VSC 9.7P2 vCenter Server 6.5 and later Issue Unable to enable SRA with error: Error updating capabilities, due to internal processing exception: Unable to connect to VMware Profile Driven Storage Service. Please verify that the service is running appropriately Unable to find valid certification path to requested target occurred as provider: https://xx.xx.xx.xx:9090/version.xml is offline