Skip to main content
NetApp Knowledge Base

Search

  • Filter results by:
    • View attachments
    Searching in
    About 18 results
    • https://kb.netapp.com/data-mgmt/SnapCenter/SC_KBs/SCV_has_one_or_more_resources_that_are_not_supported
      Adding Datastore or Virtual Machine (VM) to Resource Group fails: Some entities are not SnapCenter compatible Selected virtual machine is not SnapCenter compatible 1)All the Datastores and VMDK files ...Adding Datastore or Virtual Machine (VM) to Resource Group fails: Some entities are not SnapCenter compatible Selected virtual machine is not SnapCenter compatible 1)All the Datastores and VMDK files used by VM are not on supported storage. 2)All NetApp Storage Virtual Machine (SVMs) related to Datastores or VM are not registered within Task 'Discovering Resources' failed with error: Unable to discover resources on SCV: Failed to determine LUN based on the serial number
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/SELECT__reclaiming_capacity_after_disk_detach
      NetApp ONTAP Select Deploy Removing disks outside of the Deploy tool will result in unreclaimed capacity. When the disk is not detached correctly, the changes won`t get properly updated in the Deploy ...NetApp ONTAP Select Deploy Removing disks outside of the Deploy tool will result in unreclaimed capacity. When the disk is not detached correctly, the changes won`t get properly updated in the Deploy utility and capacity will not be reclaimed: (ONTAPdeploy) node storage disk show -cluster-name lgabor_cl1 -node-name lgabor_cl1-01 | Name | Logical Name | Capacity | Pool | ONTAP Name | | lgabor_cl1-01_4.vmdk | - | 1 TB | Datastore 2 | - | | lgabor_cl1-01_5.vmdk | - | 1 TB | Datastore 2 | - |
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/What_impact_an_ESXi_upgrade_have_on_running_Ontap_Select_VMs
      ONTAP Select VMware ESXi The expected behavior is depending on cluster deployment. Please contact VMware support or check VMware documentation for more information. The procedure might be disruptive f...ONTAP Select VMware ESXi The expected behavior is depending on cluster deployment. Please contact VMware support or check VMware documentation for more information. The procedure might be disruptive for single-node cluster as drivers and firmware updates are in play on a single ESXi host. The procedure can be non-disruptive if using 2-node cluster (HA pair) with nodes running on different hosts. Upgrading first one ESXi host and then the other, should maintain availability of the HA pair.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Windows_virtual_machine_crashes_on_VMware_ESXi
      Applies to NetApp HCI VMware ESXi Microsoft Windows 10 Microsoft Windows Server 2019 PVSCSI driver v 1.3.15.0 or lower VMware Tools 11.2.x or lower Issue Windows VMs crash unexpectedly. On Event Viewe...Applies to NetApp HCI VMware ESXi Microsoft Windows 10 Microsoft Windows Server 2019 PVSCSI driver v 1.3.15.0 or lower VMware Tools 11.2.x or lower Issue Windows VMs crash unexpectedly. On Event Viewer logs, there are pvscsi warning events: Warning <date of the event> pvscsi <event ID> <task category> On vmware.log: 2021-01-25T19:16:46.358Z| vcpu-0| I125: Tools: Tools heartbeat timeout Full vmware.log output in Additional Information
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/ONTAP_Select_system_went_offline_after_LUNs_went_offline
      Applies to ONTAP Select vCenter ESXi LUNs Issue ONTAP Select vm has gone offline after LUNs went offline
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/HostVMLookupFailed__Failed_to_look_up_VM_information_on_host
      Applies to ONTAP Select Deploy VMware vCenter VMware ESX Issue Deploy cluster refresh operation fails with an error: [HostVMLookupFailed: Failed to look up VM information on host <host_name>.Reason: "...Applies to ONTAP Select Deploy VMware vCenter VMware ESX Issue Deploy cluster refresh operation fails with an error: [HostVMLookupFailed: Failed to look up VM information on host <host_name>.Reason: "You are attempting to access resources on a host using the host credentials, however, that host is under vCenter Control.Remove the host from ONTAP Select Deploy and add it using the proper vCenter credentials".] [Refresh operation for cluster <cluster_name> failed.].
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/ONTAP_Select_Deploy__NodeDetachDiskFailed_as_a_result_of_dupe_VMDKs_in_the_Deploy_disk_inventory
      <SDOTAdminError(key="NodeDetachDiskFailed", Failed to detach disk "cluster01-01_5.vmdk" from node "cluster01-01" in cluster "cluster01". Reason: Disk "cluster01-01_5.vmdk" cannot be detached from node...<SDOTAdminError(key="NodeDetachDiskFailed", Failed to detach disk "cluster01-01_5.vmdk" from node "cluster01-01" in cluster "cluster01". Reason: Disk "cluster01-01_5.vmdk" cannot be detached from node "cluster01-01". It is in use by "ONTAP". Can only detach disks that are broken, shared, spare, unassigned, or unknown.")> Unable to identify and delete the affected disk as the output of node storage disk show on the ONTAP deploy appliance shows many disks with the same name.
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/ONTAP_Select_or_CVO_Giveback_vetoed_because_aggr_is_being_resynced
      NetApp ONTAP Select (OTS) Cloud Volumes ONTAP (CVO) Giveback of ONTAP Select VM or Cloud Volumes ONTAP instance cannot complete and is vetoed by RAID module: Node Aggregate Giveback Status Warning: Un...NetApp ONTAP Select (OTS) Cloud Volumes ONTAP (CVO) Giveback of ONTAP Select VM or Cloud Volumes ONTAP instance cannot complete and is vetoed by RAID module: Node Aggregate Giveback Status Warning: Unable to list entries on node select-01. RPC: Couldn't make connection [from mgwd on node "select-02" (VSID: -1) to mgwd at xxx.xx.xxx.xxx] Giveback vetoed: Cannot the giveback without checks, use the Node management LIF cannot be accessed due to node being in takeover
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Cmd_0x89_to_dev_on_path_Failed__H_0x0_D_0x2_P_0x0_Valid_sense_data__0xe_0x1d_0x0
      Applies to VMware ESXi 5.5 and newer iSCSI VMFS 5 and 6 Issue vmkernel.log contains nmp_ThrottleLogForDevice type messages for failing ATS heartbeats due to MISCOMPARE in the check condition from stor...Applies to VMware ESXi 5.5 and newer iSCSI VMFS 5 and 6 Issue vmkernel.log contains nmp_ThrottleLogForDevice type messages for failing ATS heartbeats due to MISCOMPARE in the check condition from storage Example: cpu47:4103824)NMP: nmp_ThrottleLogForDevice:3647: Cmd 0x89 (0x439d87291800, 67336) to dev "naa.600a09803830393053244b7478695835" on path "vmhba1:C0:T26:L43" Failed: H:0x0 D:0x2 P:0x0 Valid sense data: 0xe 0x1d 0x0. Act:NONE
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/vNIC_disconnected_after_vSphere_HA_failover_or_vMotion_and_reconnecting_vNIC_fails
      Applies to NetApp HCI VMware ESXi 6.5 VMware distributed switch (vDS) HA failover / Vmotion Issue After initiating vSphere HA failover, some of the virtual machines are powered on with virtual network...Applies to NetApp HCI VMware ESXi 6.5 VMware distributed switch (vDS) HA failover / Vmotion Issue After initiating vSphere HA failover, some of the virtual machines are powered on with virtual network interface card (vNIC) disconnected to vDS Reconnecting vNIC fails with error: Failed to connect virtual device ethernetX
    • https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/Unable_to_select_Storage_Pool_in_ONTAP_Select_Deploy
      Applies to ONTAP Select Deploy VMware ESXi Issue Unable to select a Datastore in the Storage Pool drop-down list when deploying a Cluster (single node, HA pair or greater):