    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/What_do_storage_system_and_shelf_temperature_thresholds_mean
      The low critical and low warnings are -1C and the high warning is 48C and the high critical is 50C. When the warning levels are reached an AutoSupport will be generated and if the critical levels are ...The low critical and low warnings are -1C and the high warning is 48C and the high critical is 50C. When the warning levels are reached an AutoSupport will be generated and if the critical levels are reached the storage system will shutdown. Sensor 1 is in the shelf, sensor 2 is in the A module and Sensor 3 is in the B module. If the warning threshold is reached, a warning AutoSupport is generated and if the critical threshold is reached on a shelf it will not power off.
    • https://kb.netapp.com/Legacy/NetApp_HCI/OS/Is_it_possible_to_change_the_error_threshold_alert_in_Active_IQ
      Applies to NetApp Element software NetApp HCI Storage nodes Answer Changing the threshold value for Error severity alerts is not supported Additional Information Check How are the blockSpace threshold...Applies to NetApp Element software NetApp HCI Storage nodes Answer Changing the threshold value for Error severity alerts is not supported Additional Information Check How are the blockSpace thresholds calculated for Element to understand how these alerts are generated and how to change the value for Warning alerts
    • https://kb.netapp.com/data-mgmt/AIQUM/AIQUM_Kbs/The_UM_volume_threshold_did_not_identify_a_volume_that_passed_the_full_or_nearly_full_threshold
      Applies to ActiveIQ Unified Manager ONTAP cluster Issue A volume ran out of space and no notification was send by UM with the full or nearly full threshold
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Sensors_LED1_or_LED2_upper_non-critical_threshold_causes_Environmental_Shutdown
      Temperature sensors LED1 and LED2 trigger an environmental shutdown when the upper non-critical threshold (43°C) has been reached, instead of the upper critical threshold that normally triggers enviro...Temperature sensors LED1 and LED2 trigger an environmental shutdown when the upper non-critical threshold (43°C) has been reached, instead of the upper critical threshold that normally triggers environmental shutdowns: [Node1: env_mgr: monitor.shutdown.chassisOverTemp:EMERGENCY]: Chassis temperature is too hot: Ambient temperature is warning high. [Node1: env_mgr: monitor.chassisTemperature.warm:alert]: Chassis temperature is too warm: LED2 Temp is warning high (43 C).
    • https://kb.netapp.com/on-prem/solidfire/hardware_Kbs/How_are_the_blockSpace_thresholds_calculated_for_Element
      This can be consulted by the raw capacity per node type on What is the raw block and metadata capacity for SolidFire and H-Series nodes? Total block capacity - (largest node capacity + 3 % of total bl...This can be consulted by the raw capacity per node type on What is the raw block and metadata capacity for SolidFire and H-Series nodes? Total block capacity - (largest node capacity + 3 % of total block capacity) = Cluster error threshold Cluster error threshold / Total block capacity = % at which the system generates the error message The system default for generating a warning severity message is 3% below the calculated error severity
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Nearly_full_EMS_event_is_not_generated_in_ONTAP_for_a_specific_volume
      Applies to ONTAP 9.x Issue EMS event for a specific volume is not present in the event log show -message-name monitor.vol* command output
    • https://kb.netapp.com/hybrid/StorageGRID/Alerts/StorageGRID_Appliance_compute_controller_chassis_reports_temperature_too_high
      A compute chassis temperature sensor is reporting higher then recommended operating conditions. Appliance compute controller chassis temperature too high The temperature of the compute controller in a...A compute chassis temperature sensor is reporting higher then recommended operating conditions. Appliance compute controller chassis temperature too high The temperature of the compute controller in a StorageGRID appliance has exceeded a nominal threshold 2bb3 | 05/31/2024 | 06:35:29 | Temperature #0x63 | Upper Non-critical going high | Asserted 2bb4 | 05/31/2024 | 06:36:11 | Temperature #0x63 | Upper Non-critical going high | Deasserted
    • https://kb.netapp.com/Legacy/OnCommand_Suite/Active_IQ_Unified_Manager_No_reservations_found_for_aggregate_on_backup_jobs_via_Commvault
      Active IQ Unified Manager 9.6 ( AIQUM ) Active IQ Unified Manager 9.7 ( AIQUM ) Error:[Could not reserve space on aggregate(s) '[cluster1:aggr1]' for volume 'svm1:/vol1' on storage service node 'Backu...Active IQ Unified Manager 9.6 ( AIQUM ) Active IQ Unified Manager 9.7 ( AIQUM ) Error:[Could not reserve space on aggregate(s) '[cluster1:aggr1]' for volume 'svm1:/vol1' on storage service node 'Backup'. No reservations found for aggregate 'cluster1:aggr1'. Reason: (Could not reserve space on aggregate(s) '[cluster:cluster_01_data_sas_01]' for volume 'cluster:/lun_prod2_vol' on storage service node 'Mirror'. No reservations found for aggregate 'cluster:cluster_01_data_sas_01'.