StorageGRID Appliance compute controller chassis reports temperature too high
Applies to
StorageGRID
Issue
- A compute chassis temperature sensor is reporting higher then recommended operating conditions.
- Alerts seen in StorageGRID GUI:
Appliance compute controller chassis temperature too high
The temperature of the compute controller in a StorageGRID appliance has exceeded a nominal threshol
d
- BMC log reports constant:
2bb3 | 05/31/2024 | 06:35:29 | Temperature #0x63 | Upper Non-critical going high | Asserted
2bb4 | 05/31/2024 | 06:36:11 | Temperature #0x63 | Upper Non-critical going high | Deasserted
- The sensor reporting the alert and temperature can be seen in:
/base-os-logs/var/local/gemini-system-status/status.json
"name": "Temp_Inlet",
"type": "Temperature",
"reading": "41.00",
"units": "C",
"event": "'At or Above (>=) Upper Non-Critical Threshold'"
"sensor": "Temperature Temp_Inlet",
"event": "Upper Non-critical - going high",
"details": "Reading = 41.00 C:Threshold = 41.00 C"