Applies to NetApp Element Software Remote replication Link between clusters on standard MTU Storage clusters on jumbo MTU This article describes how to fix MTU inconsistency respecting the supported m...Applies to NetApp Element Software Remote replication Link between clusters on standard MTU Storage clusters on jumbo MTU This article describes how to fix MTU inconsistency respecting the supported models for remote replication as described in TR-4741 (page 12 and further). Please note on Element software MTU inconsistency is not supported by NetApp. While it is possible the replication may work/have worked under other circumstances, only the scenarios described in TR-4741 are supported.
Applies to A700 ONTAP 9 Issue If the switch sets the MTU size as 1500, a ping test from the client with an MTU size of 1500 will fail Swithch: MTU 1500 If the switch sets the MTU size as 9192, a ping ...Applies to A700 ONTAP 9 Issue If the switch sets the MTU size as 1500, a ping test from the client with an MTU size of 1500 will fail Swithch: MTU 1500 If the switch sets the MTU size as 9192, a ping test from the client with an MTU size of 1500 will succeed Example: Netapp storage: MTU 1500 Swithch: MTU 9192 Client: MTU 1500
Applies to Data ONTAP 9 iSCSI VMware Issue After migrating to a new Nexus 5K switch the ESXi hosts lost connectivity to their LUNs. Datastores show unavailable.
The article offers a resolution for the scenario where long frames are observed in the ifstat output and an alert is triggered for vifmgr.cluscheck.crcerrors.
Applies to ONTAP Select 9.13.1 Issue VMs are mounting NFS volumes that are provisioned by the ONTAP select NFS access is unstable: The mounting process is hanging The volume access is very slow