    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Incorrect_Shelf_Sensor_Thresholds_after_maintenance_or_replacement
      Temperature thresholds by element: [1] High critical: 52 C (125 F); high warning: 47 C (116 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [2] High critical: 60 C (140 F); high warning: 55 C (13...Temperature thresholds by element: [1] High critical: 52 C (125 F); high warning: 47 C (116 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [2] High critical: 60 C (140 F); high warning: 55 C (131 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [3] High critical: 60 C (140 F); high warning: 55 C (131 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [4] High critical: 60 C (140 F); high warning: 55 C (131 F) Low critical: 0 C (32 F); low warning: 5 C (41 F) [5] High critical: 60 C …
    • https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/Link_break_detected_on_Fibre_Channel_adapter
      [NODE_NAME: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2c. [NODE_NAME: slifc_timeout_3: fci.link.error:error]: Could not recover link on Fibre Channel adapter 2c ...[NODE_NAME: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2c. [NODE_NAME: slifc_timeout_3: fci.link.error:error]: Could not recover link on Fibre Channel adapter 2c after 30 seconds. Taking the adapter offline. [NODE_NAME: nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 100000109b4e2af2 raised by monitor node-connect [NODE_NAME: slifc_asyncd_3: fci.adapter.online:info]: Fibre Channel adapter 2c is now online.
    • https://kb.netapp.com/on-prem/ontap/da/SAN/SAN-KBs/After_FLI_migration_mutiple_luns_went_offline
      After migration from VMAX to NetApp, few luns went offline with the message: Sun Jul 19 13:17:46 0300 [Cluster_1-01: ra_mlm_admin: mlm.array.lun.PathRemoved:info]: Array LUN ABC 02:3-13.126L1' (XXXXXX...After migration from VMAX to NetApp, few luns went offline with the message: Sun Jul 19 13:17:46 0300 [Cluster_1-01: ra_mlm_admin: mlm.array.lun.PathRemoved:info]: Array LUN ABC 02:3-13.126L1' (XXXXXXXXXXXXXXXXXXXXXXXX) is no longer available on initiator port 2c through EMC_SYMMETRIX_1's target port: WWNN: XXXXXXXXXX, WWPN:XXXXXXXXX
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/iSCSI_lun_lost_during_takeover_ONTAP_Upgrade
      Applies to ONTAP 9 iSCSI Issue All paths down to iSCSI LUN during takeover of ONTAP upgrade iSCSI sessions only configure to one node of the HA pair from the host
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/Can_Cisco_QSFP-4SFP10G-CU_40GbE_to_10GbE_breakout_cables_be_used_to_connect_a_NetApp_controller_to_a_Cisco_40GbE_data_switch
      Customers might need to connect their Cisco 40GbE Ethernet switch ports to NetApp FAS platforms onboard or optional NICs using a Cisco copper 4x10GbE breakout cable. The authoritative source for cable...Customers might need to connect their Cisco 40GbE Ethernet switch ports to NetApp FAS platforms onboard or optional NICs using a Cisco copper 4x10GbE breakout cable. The authoritative source for cable compatibility information is the NetApp Hardware Universe. NetApp part number X66120-3 or X66120-5 can be used as a cross-reference. Cisco part numbers for QSFP+ to 4xSFP+ copper break-out cables: QSFP-4SFP10G-CU-3M (NetApp Part Number: X66120-3) QSFP-4SFP10G-CU-5M (NetApp Part Number: X66120-5)
    • https://kb.netapp.com/Legacy/ONTAP/7Mode/7-mode_Auto-upgrade_Disk_Firmware_Failed
      Fri Aug 7 19:30:16 CST [FAS6210-5048-B:raid.disk.offline:notice]: Marking Disk 1c.125L70 Shelf 60 Bay 17 [NETAPP X412_SSKBE560A15 NA01] S/N [WFJ1WQTJ] offline. Fri Aug 7 19:30:16 CST [FAS6210-5048-B:b...Fri Aug 7 19:30:16 CST [FAS6210-5048-B:raid.disk.offline:notice]: Marking Disk 1c.125L70 Shelf 60 Bay 17 [NETAPP X412_SSKBE560A15 NA01] S/N [WFJ1WQTJ] offline. Fri Aug 7 19:30:16 CST [FAS6210-5048-B:bdfu.selected:info]: Disk 1c.125L70 [NETAPP X412_SSKBE560A15 NA01] S/N [WFJ1WQTJ] selected for background disk firmware update. Fri Aug 7 19:30:34 CST [FAS6210-5048-B:raid.disk.online:notice]: Onlining Disk 1c.125L70 Shelf 60 Bay 17 [NETAPP X412_SSKBE560A15 NA01] S/N [WFJ1WQTJ].
    • https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/NIC_port_seeing_CRC_errors_in_ifstat
      ifstat command shows high CRC errors on affected port and and EMS reports [?] Mon Apr 26 19:51:11 JST [Node-02: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0a on node Node-02 is reporting a high ...ifstat command shows high CRC errors on affected port and and EMS reports [?] Mon Apr 26 19:51:11 JST [Node-02: vifmgr: vifmgr.cluscheck.crcerrors:alert]: Port e0a on node Node-02 is reporting a high number of observed CRC errors
    • https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/Is_it_possible_to_configure_one_port_in_UTA2_port_pair_to_FC_and_other_port_to_CNA_mode
      Port pairs connected to the same ASIC must be configured in the same mode. Note: After changing the mode type of one port, the other port also gets changed. aff::> system node hardware unified-connect...Port pairs connected to the same ASIC must be configured in the same mode. Note: After changing the mode type of one port, the other port also gets changed. aff::> system node hardware unified-connect modify -node aff-01 -adapter 0c -mode cna -type target -force true.Any changes will take effect after rebooting the system. Therefore, it is not possible to configure one port in a UTA2 port pair as FC target/initiator and the other port in the CNA (FCoE target/Ethernet) mode.