Node reports StorageFCAdapterFault_Alert for down or unused FC ports
Applies to
- ONTAP 9
- MetroCluster
- FAS / AFF
- FC ports in initiator mode
Issue
- The node sends AutoSupport alerts for StorageFCAdapterFault for down FC ports after every reboot.
Health Monitor process nchm: StorageFCAdapterFault_Alert[500##########]) ALERT
- The reported port is not in use.
- The Metrocluster_Node subsystem health gets degraded:
cluster::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node degraded
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster
ok
13 entries were displayed.
- Health alert can be seen from clustershell as follows:
cluster::> system health alert show
Node: node-01
Resource: 4d
Severity: Major
Indication Time: Sat Aug 15 13:05:58 2020
Suppress: false
Acknowledge: false
Probable Cause: FC initiator adapter 4d is at fault.
Possible Effect: Resiliency of backend storage is compromised.
Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
2. Verify the operational status of the FC initiator
adapter by using the command "system node run -node