H410 Power Supply Failure detected and amber light on due to faulty 2U H-series chassis slot
Applies to
- NetApp HCI
- NetApp H410S
- NetApp H410C
Issue
H410 node in a 2U, four-node H-Series chassis is reporting Power supply unit (PSU) status as Unknown
/ Not present.
In IPMI/BMC,
- PSU alerts logged on the node's BMC Health Event Log
Power supply(PS1 Status) Power Supply Failure detected - Assertion.
Power supply(PS2 Status) Power Supply Failure detected - Assertion.
- Power Source page, Power supply status shows as
Not present
. - Sensor Reading page, the Power supply information is either not displayed or its status shows as
Not present.
- Hardware Information page, PSU status shows as
Unknown
. - Node has an amber red light on.
- Node is up and no cluster faults reported.
- PSU alert is not reported for the other nodes in the chassis
NOTE :
- reseated the power supplies one at a time.
- performed node power drain.
- Moved the node to an empty slot in another chasssis, this resolved the amber LED and PSU status & alerts.