Skip to main content
NetApp Knowledge Base

VMware Host showing frame loss and Brocade switch showing c3timeout TX on port

Views:
515
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

  • VMware ESXi 6.X
  • VMware ESXi 7.X
  • Brocade Switch

Issue

  • VMware ESXi host HBA port shows incrementing Invalid CRC Count and Invalid TX Word Count.
Adapter: vmhba1
Tx Frames: 2929696924
Rx Frames: 3782738436
Lip Count: 0
Error Frames: 0
Dumped Frames: 0
Link Failure Count: 21
Loss of Signal Count: 1
PrimSeq Protocol Err Count: 0
Invalid Tx Word Count: 524313192
Invalid CRC Count: 294694
Input Requests: 305122439
Output Requests: 299737927
Control Requests: 0
Tue Jan 25 06:42:07 UTC 2022
 
 
  • Brocade shows c3timeouts

    frames      enc   crc    crc    too    too    bad    enc   disc   link   loss   loss   frjt   fbsy  c3timeout    pcs
    tx     rx   in    err    g_eof  shrt   long   eof     out   c3    fail    sync   sig                 tx    rx    err
20: 1.3g 397.0m   0      0      0      0      0      0      0   5.9k   0      0      0      0      0     5.9k   0      0

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.