After switch reboot, CLUSTER NETWORK DEGRADED ALERT seen in ASUP
Applies to
CN1610
Issue
- CN1610 switches rebooted after a power outage or maintenance.
- The NetApp system reports (
CLUSTER NETWORK DEGRADED
) - If using ISL LAG (link aggregate), you may see this ASUP alert:
(Health Monitor process cshm: SwitchIfIslDownWarn_Alert[<switch_name>/<LAG_name>]) ALERT
- Switch
show tech-support
reports ISL ports disabled and down:
0/13 PC Mbr Disable 10G Full Down Enable Enable long
0/14 PC Mbr Disable 10G Full Down Enable Enable long
0/15 PC Mbr Disable 10G Full Down Enable Enable long
0/16 PC Mbr Disable 10G Full Down Enable Enable long
-
In the switch's
show running-config
we see shutdown on all ISL portsinterface 0/13
shutdown
description 'ISL member port 13'
mtu 9216
exit
interface 0/14
shutdown
description 'ISL member port 14'
mtu 9216
exit
interface 0/15
shutdown
description 'ISL member port 15'
mtu 9216
exit
interface 0/16
shutdown
description 'ISL member port 16'
mtu 9216
exit