Skip to main content

NetApp_Insight_2020.png 

NetApp Knowledgebase

Brocade Switch is in hung state with transient i2c faults

Views:
53
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
san
Last Updated:

Applies to

Brocade 6520

Prior to v7.3.1a or v7.4.0 

Issue

I2C access failures leading to various symptoms such as:

  1. slotshow command output may flag some components with an "*", indicating no i2c access to that component.
  2. switchshow command output may indicate “Speed Mismatch / Incompatible SFP
  3. tempshow command output may display "unknown"
  4. Console log (dmesg) may include:

pcf954x_select_mux: Failed to select the I2C mux (addr=76, val=08, err=-1 id=0)!

• In the RAS logs, look for the below errors.
 [HIL-5010], 17389714/0, CHASSIS, WARNING, Brocade6520, Warning, license id access problems (-4)!!, hil_sb_wwn_conf, line:   232, comp:secd, 
 [LIC-5015], 17389715/0, CHASSIS, ERROR, Brocade6520, Failed to get WWN from HIL. Return code -4 . , id.c, line: 80,      comp:secd, 
 [LIC-5002], 17389716/0, CHASSIS, ERROR, Brocade6520, Error reading license records. , db.c, line: 314, comp:secd, 
 [EM-5010], 17389717/0, CHASSIS, WARNING, Brocade6520, wwn card slot_out ignored for onboard fru seeprom, OID:0x46100000,   power.c, line: 3414, comp:emd, 

 