Search
- Filter results by:
- View attachments
- https://kb.netapp.com/Support/General_Support/NetApp_Authenticated_File_Upload_Release_NotesApplies to NetApp Products Description New features for NetApp Authenticated File Upload releases are discussed on this page. For general guidance on uploading via NetApp Authenticated File Upload, re...Applies to NetApp Products Description New features for NetApp Authenticated File Upload releases are discussed on this page. For general guidance on uploading via NetApp Authenticated File Upload, refer to these instructions.
- https://kb.netapp.com/on-prem/ontap/OHW/OHW-KBs/sysconfig_a_reports_Shelf_Serial_Number_instead_of_Shelf_ID_after_IOM_reseat_replacementsysconfig -a displays shelf serial number instead of the shelf ID in front the disks: sasadmin expander_map might display an invalid/alternate shelf ID : Level 10: WWN 50050cc104fd6d3f, ID 150, Serial...sysconfig -a displays shelf serial number instead of the shelf ID in front the disks: sasadmin expander_map might display an invalid/alternate shelf ID : Level 10: WWN 50050cc104fd6d3f, ID 150, Serial Number ' SHM09797XXXXX', Product 'DS424IOM3 ', Rev '0172', Slot B You might receive a duplicate shelf ID error in the messages log: [sas.shelf.conflict:error]: At least two SAS disk shelves have the same disk shelf ID.
- https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/How_to_make_symbolic_links_widelinks_work_for_CIFS_clients_on_ONTAPIf the link points to a different export, and all clients mount that alternate export over the same mount point, all other NFS clients will again observe the same behavior when traversing the link. If...If the link points to a different export, and all clients mount that alternate export over the same mount point, all other NFS clients will again observe the same behavior when traversing the link. If a symbolic link is absolute, or points to a different export, a mapping rule can be created to make sure the links resolve CIFS clients to the appropriate destination (be it a different CIFS share on the same node, or a share on a different CIFS server).
- https://kb.netapp.com/hybrid/FlexPod/VMware_vSphere_The_mount_request_was_denied_by_the_NFS_serverApplies to ONTAP VMware vSphere Issue When you attempt to create a NFS datastore, the operation fails with the error The mount request was denied by the NFS server. Example:
- https://kb.netapp.com/data-mgmt/OTV/VASA_Provider_Kbs/VASA_Provider__The_operation_is_not_allowed_in_the_current_state_of_the_datastoreApplies to NetApp VASA Provider 6.2 NetApp VASA Provider 7.x NetApp VASA Provider 9.x Issue Tasks on a vCenter datastore fail with the error "The operation is not allowed in the current state of the d...Applies to NetApp VASA Provider 6.2 NetApp VASA Provider 7.x NetApp VASA Provider 9.x Issue Tasks on a vCenter datastore fail with the error "The operation is not allowed in the current state of the datastore." The problematic datastore also has a triggered alarm of "Thin-provisioned volume capacity threshold exceeded." Example:
- https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/MetroCluster_Storage_Virtual_Machines_stop_after_a_cluster_reboot_or_an_unplanned_power_outageAll nodes in the cluster rebooted at the same time After an unplanned power outage or reboot of all controllers in 1 cluster of a MetroCluster, all Storage Virtual Machines (SVM) are marked as stopped...All nodes in the cluster rebooted at the same time After an unplanned power outage or reboot of all controllers in 1 cluster of a MetroCluster, all Storage Virtual Machines (SVM) are marked as stopped when the nodes are back online. Attempting to start the servers result in the following error: cluster1::> vserver start -vserver vserver1 Error: command failed: Failed to start Vserver "vserver1" because the management configuration for this Vserver is locked.
- https://kb.netapp.com/data-mgmt/OTV/VSC_Kbs/VMware_Atomic_Test_and_Set_heartbeats_impact_connectivity_to_storage2022-04-04T12:33:16.355Z cpu1:2097617)NMP: nmp_ThrottleLogForDevice:3872: Cmd 0x89 (0x45bac31031c0, 2097193) to dev "naa.600a09803831364468244e4c5a47494e" on path "vmhba64:C1:T0:L0" Failed: H:0x5 D:0x...2022-04-04T12:33:16.355Z cpu1:2097617)NMP: nmp_ThrottleLogForDevice:3872: Cmd 0x89 (0x45bac31031c0, 2097193) to dev "naa.600a09803831364468244e4c5a47494e" on path "vmhba64:C1:T0:L0" Failed: H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0. 2022-04-04T12:43:13.402Z cpu2:2097617)NMP: nmp_ThrottleLogForDevice:3872: Cmd 0x89 (0x45baf1751140, 2097193) to dev "naa.600a09803831364468244e4c5a47494e" on path "vmhba64:C0:T0:L0" Failed: H:0x5 D:0x0 P:0x0 Invalid sense data: 0x0 0x0 0x0.
- https://kb.netapp.com/on-prem/ontap/ontap-select/Select-KBs/ONTAP_select_serving_LUNs_may_panic_when_high_amount_of_data_is_written_to_datastoreApplies to ONTAP Select vSAN VMware Issue When a high amount of writes occur (on datastore VMFS-6) which causes VMDK to grow, the operation hangs up and ONTAP is rebooted with the following panic mess...Applies to ONTAP Select vSAN VMware Issue When a high amount of writes occur (on datastore VMFS-6) which causes VMDK to grow, the operation hangs up and ONTAP is rebooted with the following panic message: WAFL hung for <volname>. in SK process wafl_exempt01 on release 9.x (C) Normally a core dump will be generated which can be uploaded to a new or existing NetApp case to match it to this particular issue.
- https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_compare_SNMPv3_settings_between_ONTAP_and_Brocade_SwitchApplies to Brocade FC Switch MetroCluster ONTAP 9 SNMPv3 Description For ONTAP to be able to monitor a switch the following must match: snmp username authentication protocol privacy protocol password
- https://kb.netapp.com/data-mgmt/OTV/VSC_Kbs/How_to_gather_logs_for_VSC_pluginApplies to Virtual Storage Console (VMware) 7.x Virtual Storage Console (VMware) 9.x Description This article describes the procedure that should be followed to gather logs for the Virtual Storage Con...Applies to Virtual Storage Console (VMware) 7.x Virtual Storage Console (VMware) 9.x Description This article describes the procedure that should be followed to gather logs for the Virtual Storage Console (VSC) plugin. This procedure includes instructions for both the vSphere WebClient and vSphere HTML5 UI (user interface). Note: If the Virtual Storage Console interface is not visible,see the following KB on how to collect logs manually
- https://kb.netapp.com/on-prem/ontap/mc/MC-KBs/How_to_increase_SyncMirror_resync_speedApplies to SyncMirror ONTAP 9.3+ Cloud Volumes ONTAP(CVO) on Amazon Web Services (AWS) ONTAP Select Description In certain circumstances, the default speed for resyncing a syncmirror plex might not be...Applies to SyncMirror ONTAP 9.3+ Cloud Volumes ONTAP(CVO) on Amazon Web Services (AWS) ONTAP Select Description In certain circumstances, the default speed for resyncing a syncmirror plex might not be fast enough to complete within a maintenance window using the default settings.