Issue

After making zone changes in the fabric, the customer may encounter one or more of the following:

  • Defined zone configuration DB is removed, HA Sync is lost, and verify error seen on standby CP.
  • Fabric is segmented with reason "segment zone conflict"
  • Errors in the logs:

2020/03/27-10:46:03, [ZONE-1062], 2850, FID 128, WARNING, switch, Defined and Effective zone configurations are inconsistent.
2020/03/27-10:46:17, [RCS-1006], 2851, FID 128, INFO, switch, State 2, Application Zoning AD0, RCS CM. Domain 7 returned 0x8. App Response Code 3.
2020/03/27-10:46:17, [ZONE-1019], 2852, FID 128, ERROR, switch, Transaction Commit failed.  Reason code 3 (3) - "Sfc Was Rejected: Remote Switch Unable To Process".

  •  An extra semicolon is left at the end of the zone member list