Issue

  • "cf.rv.notConnected" and "nv.partner.size.mismatch" occurs on both nodes.
  • EMS log reports below.

Example:

[?] Sun Mar 21 05:04:58 +0900 [Node-1: raidio_thread: nvmm.mirror.aborting:debug]: mirror of sysid 1, partner_type HA Partner and mirror state MIRROR_ONLINE is aborted because of reason Abort Pending.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nvram_sync: nvmm.mirror.offlined:debug]: params: {'mirror': 'HA Partner Mirror Offlined'}
[?] Sun Mar 21 05:04:58 +0900 [Node-1: rendezvous_proc: cf.rv.notConnected:alert]: HA interconnect: Connection for 'cfo_rv' failed.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nic_mgr: cf.nm.nicViError:info]: HA interconnect: NIC 0 has an error on RAID VI (virtual interface #9): SEND_DESC_TIMEOUT 12.
[?] Sun Mar 21 05:04:58 +0900 [Node-1: nic_mgr: cf.nm.nicReset:notice]: HA interconnect: Initiating soft reset on card 0 due to rendezvous reset.
[?] Sun Mar 21 05:04:59 +0900 [Node-1: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'progresscounter': '0', 'newstate': 'SF_UNKNOWN', 'prevstate': 'SF_UP'}
[?] Sun Mar 21 05:04:59 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).

[?] Sun Mar 21 05:05:01 +0900 [Node-1: nvram_sync: nvmm.mirror.disabled:debug]: params: {'mirror': 'HA Partner Mirror Disabled'}
[?] Sun Mar 21 05:05:01 +0900 [Node-1: nvram_sync: nv.partner.size.mismatch:alert]: CF monitor: NVRAM size mismatch between nodes detected; node requires 661651456 bytes, partner exported 0 bytes.
[?] Sun Mar 21 05:05:02 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (NVRAM size mismatch).
[?] Sun Mar 21 05:05:05 +0900 [Node-1: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of Node-2 disabled (NVRAM size mismatch).

  • Error recovers automatically.

Example:

[?] Sun Mar 21 05:05:05 +0900 [Node-1: rv_assist_proc: ems.engine.suppressed:debug]: Event 'cf.rv.flush.handleExchange' suppressed 2 times in last 2809539 seconds.
[?] Sun Mar 21 05:05:05 +0900 [Node-1: rv_assist_proc: cf.rv.flush.handleExchange:info]: HA interconnect: Flushing is active.
[?] Sun Mar 21 05:05:06 +0900 [Node-1: rv_assist_proc: nvmm.mirror.enabled:debug]: params: {'mirror': 'HA Partner Mirror Enabled'}
[?] Sun Mar 21 05:05:06 +0900 [Node-1: rendezvous_proc: cf.rv.connected:info]: HA interconnect: Connection for 'cfo_rv' succeeded.
[?] Sun Mar 21 05:05:06 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerDisabled:error]: Failover monitor: takeover of Node-1 by Node-2 disabled (unsynchronized log).
[?] Sun Mar 21 05:05:06 +0900 [Node-1: cf_firmware: cf.fm.partnerFwTransition:info]: params: {'progresscounter': '2816232', 'newstate': 'SF_UP', 'prevstate': 'SF_UNKNOWN'}
[?] Sun Mar 21 05:05:07 +0900 [Node-1: cf_main: cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of Node-2 disabled (unsynchronized log).
[?] Sun Mar 21 05:05:12 +0900 [Node-1: nvram_sync: nvmm.mirror.onlined:debug]: params: {'mirror': 'HA Partner Mirror Onlined'}
[?] Sun Mar 21 05:05:12 +0900 [Node-1: cf_main: cf.fsm.takeoverByPartnerEnabled:notice]: Failover monitor: takeover of Node-1 by Node-2 enabled

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.