Weekly SPARES_LOW error for a Flash Pool or Storage Pool aggregate
Applies to
- ONTAP 9.7 or later
- Flash Pool / Storage Pool Aggregate (Hybrid aggregate)
Issue
- After upgrading ONTAP to 9.7P14, the system triggers a warning once per week:
Fri Jun 25 11:53:00 +0200 [node-01: monitor: monitor.globalStatus.nonCritical:error]: There are no enough spare disks.
Fri Jun 25 12:00:00 +0200 [node-01: config_thread: callhome.spares.low:error]: Call home for SPARES_LOW
- No drive failures.
- No additional drives added to any of the existing hybrid aggregates.
- The hybrid aggregate uses RAID4 groups:
Aggregate data_aggr (online, mixed_raid_type, hybrid) (block checksums)
Plex /data_aggr/plex0 (online, normal, active, pool0)
RAID group /data_aggr/plex0/rg0 (normal, block checksums, raid_dp)
RAID group /data_aggr/plex0/rg1 (normal, block checksums, raid4)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
parity 0b.00.1P1 0b 0 1 SA:A 0 SSD N/A 228853/468690944 228861/468707328
...
data 0b.00.3P1 0b 0 3 SA:A 0 SSD N/A 228853/468690944 228861/468707328
RAID group /data_aggr/plex0/rg2 (normal, block checksums, raid4)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
parity 0b.00.1P2 0b 0 1 SA:A 0 SSD N/A 228853/468690944 228861/468707328
...
data 0b.00.3P2 0b 0 3 SA:A 0 SSD N/A 228853/468690944 228861/468707328
- No spare drives available for the RAID groups with SSDs