Issue

  • System reports Single-Path when cabled for Multi-Path.
  • IOM6 and IOM12 are mixed in the same stack. 
    • Verify compatibility: HWU . Go to Storage Limits > Full Storage Limit Matrix >Supported Shelves/Drives
  • If the cabling is not correct the system might trigger an EMS message similar to:

[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = IOM12ToIOM6SquarePortConnection_Alert , Alerting Resource = 1234567..... raised by monitor node-connect
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = MixOfIOMAandIOMBConnection_Alert , Alerting Resource = 1234567.....:2 raised by monitor node-connect
[Node-01: nchmd: hm.alert.raised:alert]: Alert Id = SinglePathToDiskShelf_Alert , Alerting Resource = 1234567..... raised by monitor node-connect

 

  • The port where the IOM6 Square port is connected to will be disabled:

Shelf name:    Partner.shelf0
Shelf id:      0
Channel:       Partner
Module:        A
               Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk    Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id     State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
[SQR0] NO SIGNAL      7         NA        0           0       0        0         0       6
[SQR1] NO SIGNAL      7         NA        0           0       0        0         0       6
[SQR2] NO SIGNAL      7         NA        0           0       0        0         0       6
[SQR3] NO SIGNAL      7         NA        0           0       0        0         0       6

Shelf name:    0b.shelf1
Shelf id:      1
Channel:       0b
Module:        A
               Partial Path   Link    Invalid   Running     Loss    Phy       CRC     Phy
Disk    Port   Timeout        Rate     DWord    Disparity   Dword   Reset     Error   Change
Id     State   Value (ms)    (Gb/s)    Count    Count       Count   Problem   Count   Count
--------------------------------------------------------------------------------------------
[HST8] DIS/ILLGL      7         NA        0           0       0        1         0       4
[HST9] DIS/ILLGL      7         NA        0           0       0        0         0       4
[HST10] DIS/ILLGL      7         NA        0           0       0        1         0       4
[HST11] DIS/ILLGL      7         NA        0           0       0        1         0       4

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.