In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

E-Series controller in lockdown state (0E L0 or 06 L0) due to in invalid device in alternate controller

Views:
866
Visibility:
Public
Votes:
0
Category:
e-series-systems
Specialty:
esg
Last Updated:

Applies to

  • All E-Series Hardware Platforms

Issue

Controller is locked down with a 7-segment LED code of either OE L0 or 06 L0 on the back of controller.

The codes indicate the controller is locked down due to hardware mismatch.

-> spriSevenSegShow
Code: 0E L0
Condition: This controller is paired with an invalid device in its alternate controller slot. Replace the in correct controller canister device with a matching
value = 162 = 0xa2


The following error messages may be displayed in the boot sequence (console output) and the debug queue logs:


CtrlMismatchErrType: Ctlr board id:0x15, Alt ctlr board id:0x10
CtrlMismatchErrType: MISMATCH - Controller Board ID=0x15, AltID=0x10

 

 

 

 

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support