Issue

Controller is locked down with a 7-segment LED code of either OE L0 or 06 L0 on the back of controller.

The codes indicate the controller is locked down due to hardware mismatch.

-> spriSevenSegShow
Code: 0E L0
Condition: This controller is paired with an invalid device in its alternate controller slot. Replace the in correct controller canister device with a matching
value = 162 = 0xa2


The following error messages may be displayed in the boot sequence (console output) and the debug queue logs:


CtrlMismatchErrType: Ctlr board id:0x15, Alt ctlr board id:0x10
CtrlMismatchErrType: MISMATCH - Controller Board ID=0x15, AltID=0x10

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.