Skip to main content
NetApp Knowledge Base

vscan scan-failed errors

Views:
698
Visibility:
Public
Votes:
1
Category:
ontap-9
Specialty:
nas
Last Updated:

Applies to

  • Symantec Protection Engine 8.0 (20220702.2) (SPE)
  • ONTAP AV Connector
  • ONTAP 9

Issue

  • In ONTAP, vscan show-events lists event type scan-failed with scan engine status code 333300001 (VSENGINE_INTERNAL_ERROR)
::*> vscan show-events -vserver xxxxx
  (vserver vscan show-events)
Vserver     Node            Server         Event Type        Event Time
----------- --------------- --------------- ----------------- -----------------
xxxxx       node-01         xxx.xxx.xxx.xxx scan-failed       7/14/2022 14:28:58
xxxxx       node-01         xxx.xxx.xxx.xxx scan-failed       7/14/2022 14:28:56
xxxxx       node-01         xxx.xxx.xxx.xxx scan-failed       7/14/2022 14:28:55

::*> vscan show-events -vserver xxxxx -instance
[...]
Event Type: scan-failed
File Path: pathtofile
Vscanner Vendor: symantec protection engine
               Vscanner Version: 20220702.2
       Server Disconnect Reason: -
Vserver LIF Used for Connection: xxx.xxx.xxx.xxx
        Scan Engine Status Code: 333300001
   Consecutive Occurrence Count: 1
  • SPE logs:
Sat Jul 09 11:05:22 CEST 2022, The Symantec Protection Engine has encountered a scan error
Event Severity Level : Error Scanner : Generic Result ID : 6 File name :
pathtofile Scan Duration (sec) : 0.016 Connect Duration
(sec) : 0.078 Symantec Protection Engine IP address : ipaddress Symantec Protection Engine Port number : 0 Uptime (in seconds) :
516708 Date/time of event(with millisec) : 1657357522173 Symantec Protection Engine Host Name : hostname

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.