In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

Which interface is external key manager communication using during boot?

Views:
166
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

 

External Key Manager (EKM)
ONTAP 9.7P9 and later
 

Answer

 

Uses any LIF configuration in the admin vserver
 
cluster::> vserver show -type admin
cluster::> net int show -vserver <admin-vserver>
 
 

Additional Information

- If multiple default gateways in the admin vserver, the default gateway with the lower metric will be chosen.

- Static route will force traffic over a specific default gateway

 