Run the storage failover command to determine the state:
NetApp01::> storage failover show -instance
Node: NetApp01-01
Partner Name: NetApp01-02
Node NVRAM ID: 538225768
Partner NVRAM ID: 538226498
Takeover Enabled: false
HA Mode: ha
Takeover Possible: false
Reason Takeover not Possible: Storage failover is disabled
Interconnect Up: true
Interconnect Links: RDMA Interconnect is up (Link up)
Interconnect Type: GOP (PLX PEX8725 NTB)
State Description: Connected to NetApp01-02, Takeover is not possible: Storage failover is disabled
Partner State: Up
Time Until Takeover: -
Reason Takeover not Possible by Partner: Storage failover is disabled
Auto Giveback Enabled: true
Takeover Detection Time (secs): 15
Takeover on Panic Enabled: true
Takeover on Reboot Enabled: true
Delay Before Auto Giveback (secs): 600
Press <space> to page down, <return> for next line, or 'q' to quit... q
Node:NetApp01-02
Partner Name:NetApp01-01
Node NVRAM ID: 538226498
Partner NVRAM ID: 538225768
Takeover Enabled: false
HA Mode: ha
Takeover Possible: false
Reason Takeover not Possible: Storage failover is disabled
Interconnect Up: true
Interconnect Links: RDMA Interconnect is up (Link up)
Interconnect Type: GOP (PLX PEX8725 NTB)
State Description: Connected to NetApp01-01, Takeover is not possible: Storage failover is disabled 2, Takeover is not possible: Storage failover is disabled
Partner State: Up
Time Until Takeover: -
Reason Takeover not Possible by Partner: Storage failover is disabled
Auto Giveback Enabled: true
Takeover Detection Time (secs): 15
Takeover on Panic Enabled: true
Takeover on Reboot Enabled: true
Delay Before Auto Giveback (secs): 600