Effective December 3 - NetApp adopts Microsoft’s Business-to-Customer (B2C) identity management to simplify and provide secure access to NetApp resources. For accounts that did not pre-register (prior to Dec 3) access to your NetApp data may take up to 1 hour as your legacy NSS ID is synchronized to the new B2C identity. To learn more, Read the FAQ and Watch the video. Need assistance? Complete this form and select “Registration Issue” as the Feedback Category. 
NetApp Knowledge Base

How to transition CIFS configurations when Active Directory Domain of CIFS server on 7-Mode and target SVM are different

Views:
506
Visibility:
Public
Votes:
0
Category:
7-mode-transition-tool
Specialty:
core
Last Updated:

Applies to

7-Mode Transition Tool

Description

Symptoms

7-Mode Transition Tool (7MTT) produces the following blocking error  during the precheck operation:

  • Error Code: 20142
  • Error Type: Blocking Error
  • Error Message: The Active Directory domain of the CIFS server on the 7-Mode system does not match with the Active Directory domain of the following target SVMs.
  • Corrective Action: Perform one of the following corrective actions and then rerun the operation.
    • If the Active Directory domains of the 7-Mode system and the target SVM are trusted domains, you can convert this error to a warning and continue with the transition.
    • Reconfigure CIFS server on the target SVM to use the Active Directory domain of the 7-Mode storage systems.
    • Ignore the transition of all CIFS configurations. For more information about how to ignore the transition of all CIFS configurations, see 7-Mode Transition Tool Guide.
    • If you ignore the transition of all the CIFS configurations, you must manually transition all the CIFS configurations.

Cause
The Active Directory domain of the CIFS server on the 7-Mode system does not match with the Active Directory domain of the CIFS server of the target SVM. 

7-Mode Transition Tool (7MTT) will still allow you to transition CIFS configurations; however, ensure that the domains configured for 7-Mode and target SVM are two-way trust relationship. 
Once this prerequisite is met, you can convert this blocking error to warning, and then re-run the Precheck operation to proceed with the transition. 

Note: This Precheck is implemented only from 3.0 or later versions of 7-Mode Transition Tool. 

 