Skip to main content

Coming soon...New Support-Specific categorization of Knowledge Articles in the NetApp Knowledge Base site to improve navigation, searchability and your self-service journey.

NetApp Knowledge Base

AutoSupport fails to send in ONTAP when routed through an intercluster LIF

Views:
1,398
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
core
Last Updated:

Applies to

ONTAP 9

Issue

AutoSupport messages fail to transmit. Running system node autosupport check show-details command produces results as follows:

cluster1::> system autosupport check show-details

.....

          Component: http-post-destination

             Status: failed

             Detail: HTTP/S POST connectivity check failed for destination:

                     https://support.netapp.com/asupprod/post/1.0/postAsup.

                     LibCurl Error (7): Couldn't connect to server.

.....

          Component: http-post-destination

             Status: failed

             Detail: HTTP/S POST connectivity check failed for destination:

                     http://support.netapp.com/asupprod/post/1.0/postAsup.

                     Server responded with Error: 503.

  • Check in the notifyd.log for an entry similar to the following, The [x.x.x.x] is the intercluster lif ip.

0000000e.010261d5 65c3e06f Fri Jan 13 2023 01:20:57 +08:00 [kern_notifyd:info:1346] (category: 1346:4397:deliver) (emittime: 1/13/2023 00:48:05) (message: 250-EXCH.XXXX.XXX Hello [x.x.x.x])

0000000d.00df8fa2 65c3c56c Fri Jan 13 2023 01:18:25 +08:00 [kern_notifyd:info:1346] (category: 1346:4422:deliver) (emittime: 1/13/2023 00:45:34) (message: 250-EXCH.XXXX.XXX Hello [x.x.x.x])

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

Scan to view the article on your device