Skip to main content
NetApp Knowledgebase

SensorReadingFailed alert on H410S

Views:
241
Visibility:
Public
Votes:
0
Category:
element-software
Specialty:
solidfire
Last Updated:

Applies to

  • NetApp Element Software
  • NetApp H410S (H300S, H500S, H700S)

Issue

The following errors could appear in ActiveIQ:

  • Error checking sensor for Inlet Temp (10193x)
  • Error checking sensor for FanX RPM (10193x)
  • From /usr/bin on the affected node sudo ./smc-ipmicfg -sdr would show Fail status instead of OK
  • Alternative command that can run from mNode: sudo ipmitool -I lanplus -H <node-BMC-IP-address> -U <BMC-username> -P <BMC-password> sdr)


sfadmin@NODE /usr/bin $ sudo ./smc-ipmicfg -sdr
Status | (#)Sensor                |      Reading | Low Limit | High Limit |
------ | ---------                |      ------- | --------- | ---------- |
  Fail | (4) CPU1 Temp            |          N/A |       N/A |   98C/208F |
  Fail | (71) CPU2 Temp           |          N/A |       N/A |   98C/208F |
  Fail | (138) PCH Temp           |          N/A |    5C/41F |   95C/203F |
  Fail | (205) System Temp        |          N/A |   -5C/23F |   85C/185F |