In response to the recent rise in cyber threat due to the Russian-Ukraine crisis, NetApp is actively monitoring the global security intelligence and updating our cybersecurity measures. We follow U.S. Federal Government guidance and remain on high alert. Customers are encouraged to monitor the Cybersecurity and Infrastructure Security (CISA) website for new information as it develops and remain on high alert.
NetApp Knowledge Base

H610S - BMC Self Test failed

Views:
2,703
Visibility:
Public
Votes:
1
Category:
h-series
Specialty:
solidfire
Last Updated:

Applies to

NetApp H610S

Issue

  • In some cases, you will get persistent cluster fault:

BMC Self Test failed. This may impact IPMI based services and a BIOS/BMC update may be recommended.

  • Following  entries can be seen on sf-master.info
2021-11-22T00:14:03.084577Z hci-stg-06 master-1[26236]: [EXPERR-4] [Util] 28031 GlobalPool-0 serviceshared/IpmiComponentMonitor.cpp:272:CheckHealth|BMC Self Test failed. Postponing Fault. mBmcSelfTestFailureCount=1 cNumFailedSelfTestsForFault=10
2021-11-23T13:24:28.274373Z hci-stg-06 master-1[26236]: [EXPERR-4] [Util] 28027 GlobalPool-0 serviceshared/IpmiComponentMonitor.cpp:272:CheckHealth|BMC Self Test failed. Postponing Fault. mBmcSelfTestFailureCount=1 cNumFailedSelfTestsForFault=10
2021-12-16T15:25:16.921931Z hci-stg-06 master-1[57297]: [EXPERR-4] [Util] 55937 GlobalPool-0 serviceshared/IpmiComponentMonitor.cpp:272:CheckHealth|BMC Self Test failed. Postponing Fault. mBmcSelfTestFailureCount=1 cNumFailedSelfTestsForFault=10
2021-12-16T21:18:54.078117Z hci-stg-06 master-1[57297]: [EXPERR-4] [Util] 55937 GlobalPool-0 serviceshared/IpmiComponentMonitor.cpp:272:CheckHealth|BMC Self Test failed. Postponing Fault. mBmcSelfTestFailureCount=1 cNumFailedSelfTestsForFault=10

 

  • Along with the "BMC Self Test failed" cluster fault, any or all of the following conditions may also be present:
    • BMC web GUI is inaccessible
    • Node Offline events:
      • The SolidFire Application cannot communicate with node ID <#>
      • Node Offline nodeID=<#>
    • Cannot ping or SSH to the BMC IP address
    • Persistent cluster faults related to fans, power supplies, and system sensors.  Examples:
    • Fan1A RPM is failed or missing.
    • Error checking sensor for Fan1B RPM
    • Error checking sensor for Inlet Temp
    • Error checking sensor for Exhaust Temp
    • ipmitool commands fail with errors such as:
    • Could not open device at /dev/ipmi0 or /dev/ipmi/0 or /dev/ipmidev/0: No such file or directory
    • Get SEL Info command failed: Invalid command
    • Error sending Chassis Status command: Invalid command
    • Get Channel Info command failed: Invalid command

 

Scan to view the article on your device
CUSTOMER EXCLUSIVE CONTENT

Registered NetApp customers get unlimited access to our dynamic Knowledge Base.

New authoritative content is published and updated each day by our team of experts.

Current Customer or Partner?

Sign In for unlimited access

New to NetApp?

Learn more about our award-winning Support