Answer

Throttle is calculated by 100 – (targetIOPS / maxIOPS) * 100.

Additional Information

  • Target IOPS start being smaller than maxIOPS when the system decides sacrificing maxIOPS to guarantee minIOPS of all volumes on a node.
  • AIQ Collector is collecting last 500 ms of the throttle information every 60 seconds from SolidFire Storage Cluster.
  • Please refer to NetApp SolidFire Quality of Service (QoS)  for understanding how QoS works in Element Software.

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.