Issue

  • Recovery Guru reports the following error:

Failure Entry 1: SUPPORT_CRU_NOINPUT-Recovery Failure Type Code: 97
Storage array: E2812
Component reporting problem: Power supply canister (Right)
Status: No power input
Location: Controller/Drive shelf 99
Component requiring service: Power supply canister (Right)
Service action (removal) allowed: Yes
Service action LED on component: No
Subcomponent affected: Power supply (99)

  • Storage Array Profile shows no power input for power-fan canister and power supply:

Power-Fan Canisters Detected:  2
         Power-fan canister (Left) status:  Optimal          
         Part number:                       114-00148+E0     
         Serial number:                     111111111111111  
         Date of manufacture:               Not Available    

         Power-fan canister (Right) status:  No AC power input  
         Part number:                        114-00148+E0       
         Serial number:                      222222222222222    
         Date of manufacture:                Not Available
 

  • For systems where the power supply canister includes the fans as well (i.e SG5712, E2812), then the below failure would also be reported in Recovery Guru:

Failure Entry 1: SUPPORT_CRU_NOINPUT-Recovery Failure Type Code: 97
Storage array: E2812
Component reporting problem: Power supply canister (Right)
Status: No power input
Location: Controller/Drive shelf 0
Component requiring service: Power supply canister (Right)
Service action (removal) allowed: Yes
Service action LED on component: No

  • If AutoSupport is enabled, an email is sent to the end user. In return, the user has 24 hours to respond if a support case must be opened. The email notification will be for:  E-Series Notification (Power supply failed) CRITICAL
    • Starting with SANtricity OS 11.70.3, an AutoSupport message is not dispatched if the power supply failure reason is loss of power input. However, an email is sent to the end user if email notification is configured in SANtricity System Manager (Configure mail server and recipients for alerts).

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.