Periodic BMC reset may cause hardware faults in the event log
Applies to
NetApp SolidFire
Issue
It is normal for the BMC to periodically get reset to prevent any issues with BMC processes.
Normally we only see the message "Beginning BMC cold reset and setting new reset date
".
Occasionally, hardware faults referencing fan RPM or PSU etc are generated.
The events are purely cosmetic and require no action. Event logs show hardware faults following BMC cold reset. The events clear within 60 seconds.
Example:
Event ID Event Time Type Message Service ID Node ID Drive ID Details
xxxxx 2019-10-02 20:57:56 platformHardwareEvent Beginning BMC cold reset and setting new reset date 11 - { "bmcResetDurationMinutes": 20160, "bmcResetDate": "2019-10-17T04:36:51" }
xxxxx 2019-10-02 20:57:09 platformHardwareEvent Hardware fault detected 11 - "Hardware fault ID 2431 text=Fan1A RPM is failed or missing."
xxxxx 2019-10-02 20:57:09 platformHardwareEvent Hardware fault detected 11 - "Hardware fault ID 2432 text=Fan1B RPM is failed or missing."
xxxxx 2019-10-02 20:57:09 platformHardwareEvent Hardware fault detected 11 - "Hardware fault ID 2433 text=Fan2A RPM is failed or missing."
xxxxx 2019-10-02 20:57:09 platformHardwareEvent Hardware fault detected 11 - "Hardware fault ID 2434 text=Fan2B RPM is failed or missing."
.........
xxxxx 2019-10-02 20:57:44 platformHardwareEvent Hardware fault resolved 11 - "Hardware fault ID 2431"
xxxxx 2019-10-02 20:57:44 platformHardwareEvent Hardware fault resolved 11 - "Hardware fault ID 2432"
xxxxx 2019-10-02 20:57:44 platformHardwareEvent Hardware fault resolved 11 - "Hardware fault ID 2433"
xxxxx 2019-10-02 20:57:44 platformHardwareEvent Hardware fault resolved 11 - "Hardware fault ID 2434"
Event ID Event Time Type Message Service ID Node ID Drive ID Details
xxxxx 2020-10-16 11:51:10 platformHardwareEvent Beginning BMC cold reset and setting new reset date 4 3 - { "bmcResetDurationMinutes": 20160, "bmcResetDate": "2020-10-30T02:51:10" }
xxxxx 2020-10-16 11:52:31 platformHardwareEvent Hardware event 3 "Power supply PS2 is not present."
xxxxx 2020-10-16 11:52:30 platformHardwareEvent Hardware event 3 "Power supply PS1 is not present."
xxxxx 2020-10-16 11:53:36 platformHardwareEvent Hardware event 3 "Power supply PS2 now present."
xxxxx 2020-10-16 11:53:36 platformHardwareEvent Hardware event 3 "Power supply PS1 now present."