DriveMissing for metadata drive generates core.VolReadWrite
Applies to
- NetApp Element software
- NetApp H610S
Issue
- NetApp SolidFire Active IQ reports alerts:
- Error Code:
sliceServiceUnhealthy
Details:A metadata service is unhealthy and SolidFire is attempting to migrate data away from it.
- Error Code:
driveFailed
Details:1 drive(s) with state: "DriveMissing" driveID: xx.
- Error Code:
- core.VolReadWrite-xx.xxxx.gz is generated
kern.log
reports errors:
nvme nvme0: I/O 61 QID 29 timeout, aborting
nvme nvme0: I/O 567 QID 30 timeout, aborting
nvme nvme0: I/O 520 QID 31 timeout, aborting
nvme nvme0: I/O 942 QID 32 timeout, aborting
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: Abort status: 0x0
nvme nvme0: I/O 61 QID 29 timeout, reset controller
nvme nvme0: I/O 0 QID 0 timeout, reset controller
nvme nvme0: Device not ready; aborting reset
nvme nvme0: Device not ready; aborting reset
nvme nvme0: Removing after probe failure status: -19
nvme nvme0: Device not ready; aborting reset
print_req_error: 38 callbacks suppressed
print_req_error: I/O error, dev nvme0n1, sector 1464291080
print_req_error: I/O error, dev nvme0n1, sector 3122661848