Disk failed in ONTAP Select
Applies to
- ONTAP 9
- ONTAP Select
Issue
- ONTAP select with backend connected to Dell storage where one disk failed
- sysconfig -a output
NETAPP PHA-DISK 0001 8283.1GB 512B/sect (0-2sZBoyw6NeDVWSAR88) (Failed)
- sysconfig -r output
Broken disks
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
failed 0b.8 0b - - SA:A - VMDISK N/A 8283129/16963849728 8283135/16963862520
-
Aggregate in failed state and size 0
cluster_1::> aggr show
Aggregate Size Available Used% State #Vols Nodes RAID Status
--------- -------- --------- ----- ------- ------ ---------------- -----------------------------
aggr0_root 60.22GB 2.92GB 95% online 1 cluster_1a raid0,normal
aggr1_VMD 0B 0B 0% failed 0 cluster_1a raid0,partial