Force switchover or negotiated switchover has been completed.  The following is the MCC IP switchback procedure:
  1. Power on controllers of the disaster site
  2. If using ONTAP 9.6 or later, must verify that automatic healing is completed successfully:
metrocluster operation history show
  1. If auto-healing is not completed, must perform aggregate healing manually
metrocluster heal aggregates
metrocluster heal root-aggregates
  1. Verifying that the controller is ready for a switchover by "metrocluster switchback -simulate true"
  2. Perform switchback by "metrocluster switchback -simulate"
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.