Applies to

  • NS224 disk shelf
  • NSMs (NVMe shelf modules) firmware update

Issue

  • Brief period of SCSI selection timeout errors observed on multiple disks whilst performing shelf firmware updates
  • Error messages observed in logs:


ERROR scsi.cmd.selectionTimeout: Disk device e11b.40.0.6L0: Adapter/target error: HA status 0x7: cdb 0x9a: 00000000486e3880:0001:0040. Targeted device did not respond to requested I/O. I/O will be retried.

  • Multiple disks across different shelves, adapters, and shelf ports affected
  • All aborted commands were successful on retry
  • No hardware issues reported for any disk
  • No further errors observed after the initial event

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.