SwitchSSHAccess_Alert due to network issues
Applies to
- MetroCluster
- ONTAP 9
- Cluster switches
Issue
- Cluster network switch reports in ONTAP after maintenance activity SwitchSSHAccess_Alert
::> system health alert showNode: Node-1Alert ID: SwitchSSHAccess_AlertResource: Switch1Severity: MinorIndication Time: Wed Apr 10 10:26:33 2024Suppress: falseAcknowledge: falseProbable Cause: Login failed to Ethernet switch. Cannot collect tech-support logs.Possible Effect: Ethernet switch tech-support logs are not available in AutoSupport(R) messages for troubleshooting.Corrective Actions: 1) To set up public SSH key authentication on the Ethernet switch, run the "system switch ethernet log setup-password" command.ONTAP(R) software requires one-time use of the Ethernet switch's administrative login credentials to set up the public SSH key for ONTAP access.The administrative credentials will be discarded after the setup command is complete.2) If public SSH key authentication is already configured, log in to the Ethernet switch with administrative credentials from an SSH host or serial console to investigate the login failures.3) To disable tech-support log collection, run the "system switch ethernet log disable-collection"
- Event log shows the following message: