SwitchIslIfDownWarn_Alert reported on MetroCluster IP
Applies to
- MetroCluster IP
- Cisco N9K-C9336C-FX2
Issue
system health alert show
report one ISL as downSwitchIslIfDownWarn_Alert
- Cisco Switch reports ISL port as down
Ethernet1/16 is down (Link not connected)
- Installed QSFP reports high electric current, low TX power and no RX Power
Lane Number:1 Network Lane
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 51.30 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.19 V 3.63 V 2.97 V 3.46 V 3.13 V
Current 100.00 mA + 100.00 mA 8.00 mA 83.00 mA 10.00 mA
Tx Power -5.67 dBm - 7.79 dBm -6.00 dBm 4.80 dBm -1.99 dBm
Rx Power N/A 7.79 dBm -12.36 dBm 4.80 dBm -8.32 dBm
Transmit Fault Count = 0
----------------------------------------------------------------------------
Note: ++ high-alarm; + high-warning; -- low-alarm; - low-warning