Skip to main content
NetApp Knowledge Base

StorageBridgePortDown_Alert reported in Stretch MetroCluster system

Views:
150
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

Applies to

  • ONTAP 9
  • Stretch MetroCluster

Issue

  • One of the FC ports on a node is down:
slot 1: FC Host Adapter 1c (Emulex XE201 rev. 48, <DOWN>)
Board name:        111-02455
Serial Number:     FCXXXXXX77
Firmware rev:      11.4.277.0
Host Port Id:      N/A
FC Node Name:      2:000:00109b:25b9bc
FC Port Name:      1:000:00109b:25b9bc
SFP Vendor:        AVAGO
SFP Part Number:   AFBR-57F5MZ-NA1
SFP Serial Number: AA1XXXXX1RD
SFP Capabilities:  4, 8 or 16 Gbit
Link Data Rate:    N/A
  • The ATTO bridge FC port that is connected to the above node port is also down and the bridge reports the below error:
ATTO_161.XXX.XX.XXX(200000XXXXXXXXX):FC_PORT_1 is Offline.
 
Cluster1::> storage bridge show
                                       Is        Monitor
Bridge                   Symbolic Name Monitored Status  Vendor Model                 Bridge WWN
------------------------ ------------- --------- ------- ------ --------------------- ----------------
ATTO_161.XXX.XX.XX4      Node1-br1
                                       true      ok      Atto   FibreBridge 7500N     200XXXXXXXXX7c00
ATTO_161.XXX.XX.XX5      Node1-br2
                                       true      ok      Atto   FibreBridge 7500N     200XXXXXXXXX7900
ATTO_161.XXX.XX.XX6      Node1-br3
                                       true      ok      Atto   FibreBridge 7500N     200XXXXXXXXX6600
ATTO_161.XXX.XX.XX7      Node1-br4
                                       true      error   Atto   FibreBridge 7500N     200XXXXXXXXX7b40                      
4 entries were displayed.
  • The affected node is transitioned to "Mixed Path" configuration:
NetApp Release 9.3P7: Wed Jul 25 06:16:06 EDT 2018
System ID: 0538031811 (Node-01)
System Serial Number: 45XXXXXXXX8 (Node-01)
System Rev: A4
System Storage Configuration: Mixed-Path
  • StorageBridgePortDown_Alert and FC-AL LINK_FAILURE alerts reported in the event logs:
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 1c.
[Node-01: lhm_main: callhome.fc.al.link:alert]: Call home for FC-AL LINK_FAILURE (1c)
 
[Node-01: schmd: hm.alert.raised:alert]: Alert Id = StorageBridgePortDown_Alert , Alerting Resource = 200XXXXXXXXX7b40 raised by monitor system-connect
[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: StorageBridgePortDown_Alert[200XXXXXXXXX7b40].
  • The bridge health is degraded:
Cluster1::> system health subsystem  show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     ok
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node ok
FHM-Switch        ok
FHM-Bridge        degraded
SAS-connect_Cluster ok
13 entries were displayed.
  • The link between the affected FC ports on the node and ATTO bridge remain down despite SFP and cable replacement.
  • On swapping the cables between a known good node port and the affected ATTO, the link on the ATTO bridge comes online.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.