StorageBridgePortDown_Alert reported in Stretch MetroCluster system
Applies to
- ONTAP 9
- Stretch MetroCluster
Issue
- One of the FC ports on a node is down:
slot 1: FC Host Adapter 1c (Emulex XE201 rev. 48, <DOWN>)Board name: 111-02455Serial Number: FCXXXXXX77Firmware rev: 11.4.277.0Host Port Id: N/AFC Node Name: 2:000:00109b:25b9bcFC Port Name: 1:000:00109b:25b9bcSFP Vendor: AVAGOSFP Part Number: AFBR-57F5MZ-NA1SFP Serial Number: AA1XXXXX1RDSFP Capabilities: 4, 8 or 16 GbitLink Data Rate: N/A- The ATTO bridge FC port that is connected to the above node port is also down and the bridge reports the below error:
ATTO_161.XXX.XX.XXX(200000XXXXXXXXX):FC_PORT_1 is Offline.Cluster1::> storage bridge show
Is Monitor
Bridge Symbolic Name Monitored Status Vendor Model Bridge WWN
------------------------ ------------- --------- ------- ------ --------------------- ----------------
ATTO_161.XXX.XX.XX4 Node1-br1
true ok Atto FibreBridge 7500N 200XXXXXXXXX7c00
ATTO_161.XXX.XX.XX5 Node1-br2
true ok Atto FibreBridge 7500N 200XXXXXXXXX7900
ATTO_161.XXX.XX.XX6 Node1-br3
true ok Atto FibreBridge 7500N 200XXXXXXXXX6600
ATTO_161.XXX.XX.XX7 Node1-br4
true error Atto FibreBridge 7500N 200XXXXXXXXX7b40
4 entries were displayed.- The affected node is transitioned to "Mixed Path" configuration:
NetApp Release 9.3P7: Wed Jul 25 06:16:06 EDT 2018System ID: 0538031811 (Node-01)System Serial Number: 45XXXXXXXX8 (Node-01)System Rev: A4System Storage Configuration: Mixed-PathStorageBridgePortDown_AlertandFC-AL LINK_FAILUREalerts reported in the event logs:
[Node-01: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 1c.[Node-01: lhm_main: callhome.fc.al.link:alert]: Call home for FC-AL LINK_FAILURE (1c)[Node-01: schmd: hm.alert.raised:alert]: Alert Id = StorageBridgePortDown_Alert , Alerting Resource = 200XXXXXXXXX7b40 raised by monitor system-connect[Node-01: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: StorageBridgePortDown_Alert[200XXXXXXXXX7b40].- The bridge health is degraded:
Cluster1::> system health subsystem showSubsystem Health----------------- ------------------SAS-connect okEnvironment okMemory okService-Processor okSwitch-Health okCIFS-NDO okMotherboard okIO okMetroCluster okMetroCluster_Node okFHM-Switch okFHM-Bridge degradedSAS-connect_Cluster ok13 entries were displayed.- The link between the affected FC ports on the node and ATTO bridge remain down despite SFP and cable replacement.
- On swapping the cables between a known good node port and the affected ATTO, the link on the ATTO bridge comes online.