Plex failure after ATTO SFP replacement
Applies to
- Stretch MetroCluster
- ONTAP 9
- ATTO 7500N with faulty SFP
Issue
- One of the storage connections in a stretch MetroCluster is offline
Example:
slot 1: FC Host Adapter 1d (Emulex XE201 rev. 48, <OFFLINE (hard)>)
Board name: 111-02455
Serial Number: FC54482752
Firmware rev: 12.0.378.1
Host Port Id: N/A
FC Node Name: 2:000:000000:000000
FC Port Name: 1:000:000000:000000
Link Data Rate: N/A
- Immediately after replacing the faulty SFP on the ATTO bridge, an autosupport is triggered titled
SYNCMIRROR PLEX FAILED
- A number of disks show up as FAILED in
sysconfig -r
Aggregate root (online, raid4, mirror degraded) (block checksums)
Plex /root/plex0 (offline, failed, inactive, pool0)
RAID group /root/plex0/rg0 (partial)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
parity FAILED N/A 1713523/ -
data FAILED N/A 1713523/ -
Raid group is missing 2 disks.
online
, only the plex is offline