Skip to main content
NetApp Knowledge Base

ONTAP fail to monitor Brocade switch status in MetroCluster

Views:
444
Visibility:
Public
Votes:
0
Category:
fabric-interconnect-and-management-switches
Specialty:
brocade
Last Updated:

Applies to

  • Fabric-Attached MetroCluster
  • MetroCluster backend Fabric switches
  • Brocade FOS 8.2.x/9.0.x

Issue

  • ONTAP Health Monitor report FabricSwitchUnreachable_Alert.
  • The storage switch show will display an unknown switch whose Monitor status is false.

storage-switch-show.png

  • MGWD report SNMP get fail on Brocade switch:
00000314.00f72d18 08fc3b98 Mon Feb 27 2023 01:47:18 +08:00 [kern_mgwd:info:1993] 0x845ac7b00: 0: ERR: fabricdatacollector::storage_switch: failed to get symbolic name for Brocade_xx.xx.xx.xx switch, error = SNMP request timed out. No response was received from "Brocade_xx.xx.xx.xx" over SNMP community "public". {in isPresentInProfile() at src/tables/storage_switch.cc:1560}
  • Switch errdump -a report many Detected termination of process snmpd error:
2023/02/27-01:25:59, [KSWD-1002], 811, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:7821.
2023/02/27-01:29:58, [KSWD-1002], 812, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:7942.
2023/02/27-01:31:14, [KSWD-1002], 813, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8106.
2023/02/27-01:35:35, [KSWD-1002], 814, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8342.
2023/02/27-01:37:32, [KSWD-1002], 815, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8485.
2023/02/27-01:37:47, [KSWD-1002], 816, FFDC | CHASSIS, WARNING, BrocadeG610, Detected termination of process snmpd:8616.
2023/02/27-01:37:47, [HAM-1013], 817, CHASSIS, CRITICAL, BrocadeG610, Restartable daemon (snmp (pid=8616)) died too soon. Reboot/Failover manually if necessary.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.