Node unresponsive and will not boot
Applies to
- FAS8200
- AFF-A300
- AFF-A400
- AFF-A250
- AFF-A800
- FAS2750/FAS2720
- FAS2620
- Automated Unplanned Switchover (AUSO)
Issue
- A takeover or AUSO occurs (in case of two-node MetroCluster), and the node is completely unresponsive.
- Node doesn't recover with a hard power cycle via a motherboard reseat.
- Node doesn't power up via
system power on
orsystem power cycle
via BMC/SP. - There are no active LEDs on the motherboard.
- SP/BMC report
Running Backup Firmware
and multiple sensor can not be read.
CPU0 Temp Avg failed -- C -- -- -11 C -1 C
CPU0 Temp Margin failed -- C -- -- -11 C -1 C
CPU0 Error not_available --
CPU0 Therm Trip not_available --
CPU0 Hot not_available --
Memory0 Hot not_available --
PCH Hot not_available --
P5V not_available -- mV 4245 mV 4343 mV 5660 mV 5807 mV
P3.3V not_available -- mV 2960 mV 3040 mV 3568 mV 3664 mV
PVDDQ DDR4 AB not_available -- mV 9 mV 19 mV 2454 mV 2463 mV
PVTT DDR4 AB not_available -- mV 9 mV 19 mV 2454 mV 2463 mV
PVCCP CPU0 not_available -- mV 9 mV 19 mV 2454 mV 2463 mV
P12V not_available -- mV 0 mV -- -- 15810 mV
P12V Curr not_available -- mA 0 mA -- -- 21420 mA
- The Management console and Service Processor may be inaccessible.