MetroCluster multiple shelves from single stack missing in sysconfig output
Applies to
- Fabric MetroCluster
 - ONTAP 9
 
Issue
sysconfig -a output. storage shelf show indicates that a path is missing for the affected shelves:
Shelf with multiple paths:
storage shelf show -shelf 10.73
Controller         Initiator Initiator Side Switch Port Target Side Switch Port    Target Port        TPGN    Gb/s I/O KB/s    IOPS
------------------ --------- -------------------------- -------------------------- ------------------ ------ ----- -------- -------
cl01n01           1b        switch01:2                  switch01:8             2200001097a93dc0   24    16    50545     836
cl01n01           1d        switch01:3                  switch01:9             2200001097a93f80   4     16    54515     763
Two shelves with missing path:
storage shelf show -shelf 10.74
Controller         Initiator Initiator Side Switch Port Target Side Switch Port    Target Port        TPGN    Gb/s I/O KB/s  IOPS
------------------ --------- -------------------------- -------------------------- ------------------ ------ ----- -------- -------
cl01n01           1d        switch01:3                  switch01:9             2200001097a93f80   4     16    54515     763
storage shelf show -shelf 10.75
Controller         Initiator Initiator Side Switch Port Target Side Switch Port    Target Port        TPGN    Gb/s I/O KB/s    IOPS
------------------ --------- -------------------------- -------------------------- ------------------ ------ ----- -------- -------
cl01n01           1d        switch01:3                  switch01:9             2200001097a93f80   4     16    90083     918