Skip to main content
NetApp Knowledge Base

MetroCluster fcvi.qlgc.qpErr:error after isl issue

Views:
114
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

Applies to

  • MetroCluster FC
  • ONTAP 9
  • Brocade FC switch
  • ISL/WDM issue has occurred and been resolved

Issue

  • FC-VI received QP errors occurring frequently after an ISL/WDM issue has occurred and been resolved:
Jan 01 12:00:00 clusternode01 [clusternode01: fcvi.qlgc.qpErr:error]: FC-VI adapter: FCVI driver on port 1a received QP Error. QP name = DRSOM_HB, QP index = 0xe, VI state = Error(state code = 0x3), sub-error = Timeout occured on the QP exchange(error code = 0xe). Remote node's system id = 512341234. This error has occured 4 times.
  • trunkshow on the affected switch shows a larger than expected deskew value between the trunked ISL ports:

trunkshow        :

1: 20-> 20 10:00:00:00:00:00:00:00   5 deskew 30 MASTER

21-> 21 10:00:00:00:00:00:00:00   5 deskew 15

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.