MetroCluster fcvi.qlgc.qpErr:error after isl issue
Applies to
- MetroCluster FC
- ONTAP 9
- Brocade FC switch
- ISL/WDM issue has occurred and been resolved
Issue
- FC-VI received QP errors occurring frequently after an ISL/WDM issue has occurred and been resolved:
Jan 01 12:00:00 clusternode01 [clusternode01: fcvi.qlgc.qpErr:error]: FC-VI adapter: FCVI driver on port 1a received QP Error. QP name = DRSOM_HB, QP index = 0xe, VI state = Error(state code = 0x3), sub-error = Timeout occured on the QP exchange(error code = 0xe). Remote node's system id = 512341234. This error has occured 4 times.
- trunkshow on the affected switch shows a larger than expected deskew value between the trunked ISL ports:
trunkshow :
1: 20-> 20 10:00:00:00:00:00:00:00 5 deskew 30 MASTER
21-> 21 10:00:00:00:00:00:00:00 5 deskew 15