Issue

  • SYNCMIRROR PLEX FAILED AutoSupport message is received for MetroCluster IP:

[Node-02: config_thread: raid.rg.degraded:notice]: : Raid group /aggr1_02/plex2/rg0 is degraded
[Node-02: config_thread: raid.vol.mirror.degraded:alert]: Aggregate aggr1_02 is mirrored and one plex has failed. It is no longer protected by mirroring.
[Node-02: config_thread: callhome.syncm.plex:alert]: Call home for SYNCMIRROR PLEX FAILED

  • The iSCSI connections are found to be terminated when verified using the below command:

event log show -event *”iSCSI CAM target layer's session state is changed to terminated”*

  • Fabric 2 iSCSI connections are terminated:
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:3e6c6101-aab1-11ec-a3f8-d039ea3b9999 (address: 10.1.2.3). Reason: no ping reply after 5 seconds.
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:2f048313-aab1-11ec-8d08-d039ea3b1111 (address: 10.1.2.4). Reason: no ping reply after 5 seconds.
  • Fabric 1 connections are terminated, Pool 1 disks are no longer visible and the remote plex fails:
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:3e6c6101-aab1-11ec-a3f8-d039ea3b9999 (address: 10.1.1.3). Reason: no ping reply after 5 seconds.
[Node-01: intr: ctl.session.stateChanged:notice]: iSCSI CAM target layer's session state is changed to terminated for the initiator iqn.1994-09.org.freebsd:2f048313-aab1-11ec-8d08-d039ea3b1111 (address: 10.1.1.4). Reason: no ping reply after 5 seconds.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.