MetroCluster Flexarray fails to see disks After Motherboard Replacement
Applies to
- ONTAP 9
- MetroCluster Fabric-Attached (MCC-FC) environments
- FlexArray
Issue
- After replacing the motherboard on a MetroCluster node, the node could not see any disks—neither local nor partner disks—resulting in the following symptoms: “Normal giveback not possible: partner missing filesystem disks”
- Node stuck in
initializing/waiting-for-giveback state - Partner node reports:
Normal giveback not possible: partner missing filesystem disks - Disk show -v output returns 0 disks
*> disk show -v
Local System ID: 12345678
disk show: No disks attached to system.
- Maintenance mode: sysconfig -v output for FC initiator ports (0e/0f) shows:
slot 0: FC Host Adapter 0e (QLogic 8324 rev. 2, N-port, <UP>)
Firmware rev: 8.9.1
Flash rev: 5.0.2
Host Port Id: 0x12300
FC Node Name: 5:00a:01200b:345cd6
FC Port Name: 5:00a:01234a:567bc8
SFP Vendor: AVAGO
SFP Part Number: AFBR-XXX-NA1
SFP Serial Number: AC1XXXXXY
SFP Capabilities: 4, 8 or 16 Gbit
Link Data Rate: 16 Gbit
Switch Port: ??
slot 0: FC Host Adapter 0f (QLogic 8324 rev. 2, N-port, <UP>)
Firmware rev: 8.9.1
Flash rev: 5.0.2
Host Port Id: 0x12300
FC Node Name: 5:00a:12345a:123bc4
FC Port Name: 5:00a:12332a:123bc4
SFP Vendor: AVAGO
SFP Part Number: AFBR-XXXMZ-NA1
SFP Serial Number: AC19XXXXXX
SFP Capabilities: 4, 8 or 16 Gbit
Link Data Rate: 16 Gbit
Switch Port: ??