Skip to main content
NetApp Knowledge Base

Health Monitor process nchm: StorageFCAdapterFault_Alert - AutoSupport message

Views:
353
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
MetroCluster
Last Updated:

Applies to

  • MetroCluster FC
  • ONTAP 9
  • StorageFCAdapterFault_Alert

Event Summary

StorageFCAdapterFault alerts are generated on MetroCluster Fibre Channel systems when ONTAP health monitor detects that an FC initiator port is down.

Validate

  • Check the output of system health alert show to see the current reporting errors:

Cluster01::> system health alert show
               Node: NodeA-01
           Resource: 2b
           Severity: Major
    Indication Time: Thu Aug 05 00:06:31
           Suppress: false
        Acknowledge: false
     Probable Cause: FC initiator adapter 2b is at fault.
    Possible Effect: Resiliency of backend storage is compromised.
 Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
                     2. Verify the operational status of the FC initiator adapter by using the command  
                        "system node run -node local -command storage show adapter".

 

  • Check the current status of the reporting adapter: system node run -node <node_name> -command storage show adapter <adapter>

Cluster01::> system node run -node NodeA-01 -command storage show adapter 2b

Slot:            2b
Description:     Fibre Channel Host Adapter 2b (QLogic 2532 rev. 2)
Firmware Rev:    5.4.130
FC Node Name:    2:000:0024ff:
FC Port Name:    2:100:0024ff:
FC Packet Size:  2048
Link Data Rate:  8 Gbit
SRAM Parity:     Yes
External GBIC:   No
State:           Enabled
In Use:          Yes
Redundant:       Yes

 

  • Check the switch port the adapter is connecting to: ayatem node run -node <node_name> -command sysconfig -v <adapter number>

Cluster01::> system node run -node NodeA-01 - command sysconfig -v 2

        slot 2: FC Host Adapter 2b (QLogic 2532 rev. 2, N-port, <UP>)
                Board name:        QLE2564
                Serial Number:     RFD1404U12345
                Firmware rev:      5.4.130
                Preload Rev:       2.6.0
                Host Port Id:      0x60600
                FC Node Name:      2:000:0024ff:
                FC Port Name:      2:100:0024ff:
                SFP Vendor:        FINISAR CORP.
                SFP Part Number:   FTLF1234P3BCV-QL
                SFP Serial Number: PQH123456
                SFP Capabilities:  2, 4 or 8 Gbit
                Link Data Rate:    8 Gbit
                Switch Port:       Switch_A1:6

The highlighted section indicates the switch name and port that this adapter connects to:

  • Switch name: Switch_A1
  • Switch port: 6

Resolution

Identify and correct any connectivity issue between the reporting FC port and the identified switch port.

Additional Information

additionalInformation_text

 

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.