FC initiator adapter ports offline
Applies to
- MetroCluster FC
 - ATTO FibreBridge
 - ONTAP 9
 
Issue
- Storage FC initiator ports To FC-SAS Bridge FC Link Down after node reboot.
 - The status of FC initiator is 
OFFLINE (hard) 
slot 2: FC Host Adapter 2c (Emulex XXXXX rev. 48, <OFFLINE (hard)>)
Board name:        111-0xxxxx
Serial Number:     FC529xxxxx
Firmware rev:      11.2.219.4
Host Port Id:      N/A
FC Node Name:      2:000:0090fa:xxxxxx
FC Port Name:      1:000:0090fa:xxxxxx
Link Data Rate:    N/A
slot 2: FC Host Adapter 2d (Emulex XXXXX rev. 48,<OFFLINE (hard)>)
Board name:        111-0xxxxx
Serial Number:     FC529xxxxx
Firmware rev:      11.2.219.4
Host Port Id:      N/A
FC Node Name:      2:000:0090fa:xxxxxx
FC Port Name:      1:000:0090fa:xxxxxx
Link Data Rate:    N/A
- storage port show reports 
link-downfor concerned adapters. 
Cluster_01::*> storage port show
Speed
Node               Port Type (Gb/s) State    Status
------------------ ---- ---- ------ -------- ---------------
Cluster_01
0a   SAS       0 enabled  offline
2b   FC       16 enabled  online
2c   FC        1 enabled  link-down
2d   FC        1 enabled  link-down
- system health alert show indicates health alert on concerned adapter port.
 
system health alert show
               Node: Cluster_01
           Resource: 2d
           Severity: Major
    Indication Time: Tue Dec 26 01:25:29 2023
           Suppress: false
        Acknowledge: false
     Probable Cause: FC initiator adapter 2d is at fault.
    Possible Effect: Resiliency of backend storage is compromised.
 Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
                     2. Verify the operational status of the FC initiator
                     adapter by using the command "system node run -node
                     local -command storage show adapter".
               Node: Cluster_01
           Resource: FC_PORT_2
           Severity: Major
    Indication Time: Tue Dec 26 01:22:30 2023
           Suppress: false
        Acknowledge: false
     Probable Cause: The port "FC_PORT_2" on the bridge
                     "ATTO_X.X.X.X" is offline.
    Possible Effect: Failure of the port "FC_PORT_2" in the bridge
                     "ATTO_X.X.X.X" might cause loss of redundancy.
 Corrective Actions: 1) Check the operational status of the ports on the bridge by using the command "storage bridge show -ports".
                     2) Verify logical and physical connectivity to the port.
 
storage bridge show -portscommand shows bridge port as offline.
Cluster_01::*> storage bridge show -ports
     Bridge Name: ATTO_X.X.X.X
      Bridge WWN: 200000108xxxxxxx
          Vendor: Atto
           Model: FibreBridge 7500N
   Serial Number: FB7500NXXXXX
Firmware Version: 2.96 012U 125.06
   Management IP: X.X.X.X
          Errors: ATTO_X.X.X.X(200000108xxxxxxx):FC_PORT_2 is Offline.
                  ATTO_X.X.X.X(200000108xxxxxxx):Bridge is Unreachable over Management Network.
Last Update Time: 12/26/2023 01:59:49 +08:00
FC Ports:
      Admin    Oper                      Neg
Ports Status   Status  Port Mode       Speed WWPN
----- -------- ------- ------------- ------- ----------------
    1 enabled  online  n-port           16gb 210000108xxxxxxx
    2 enabled  offline unknown       unknown 220000108xxxxxxx
- Swap cable from working FC initiator port to the bad port to verify the cable and SFPs.
 