Applies to

  • Fabric MetroCluster
  • FC-VI adapter
  • Brocade switch

Issue

  • sysconfig -a shows FCVI link down

slot 0: FCVI Host Adapter 0e (QLogic 8324(2672) rev. 2, unknown) Physical link:DOWN

  • switchshow on switch shows connected port is disabled

34 34 032200 id N32 No_Light FC Disabled (Persistent)

  • sfpshow on switch shows no SFP or disabled

=============
Port 34:
=============
Port 34 does not use an SFP or is disabled!

  • The following message is seen in errdump on the switch

CHASSIS, WARNING, MS-G620, fabsys_media_i2c_op: Media Data validation failed:: OID 0x12345678 unit 0 port 34

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 