Issue

  • Health monitor alert triggered titled InterconnectAdapterOfflineAlert:
Example:
Cluster1::> system health alert show
               Node: Cluster1-01
           Alert ID: InterconnectAdapterOfflineAlert
           Resource: fcvi_device_3
           Severity: Major
    Indication Time: Sat Nov 16 10:24:11 2024
           Suppress: false
        Acknowledge: false
     Probable Cause: Physical link on port 5a is offline.

Node         Adapter Name    Type    Status  IP Address  Port Number
------------ --------------- ------- ------  ----------- -----------
Cluster1-01  fcvi_device_1   FC-VI   Down                5c
  • After an ONTAP upgrade, one FCVI port does not come back online
Example:
ClusterA::> metrocluster interconnect adapter show
                             Adapter Link
Node         Adapter Name    Type    Status  IP Address  Port Number
------------ --------------- ------- ------  ----------- -----------
ClusterA-01
             fcvi_device_0   FC-VI   Up      1.2.3.4     5d
ClusterA-01
             fcvi_device_1   FC-VI   Down                5c
...

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.