Duplicate ATTO Bridge entry in storage bridge show output after replacement
Applies to
- ONTAP 9
- ATTO FibreBridge 7X00N
Issue
- After an ATTO Bridge replacement, 2 entries for the same ATTO Bridge are listed in the
storage bridge show
output
Example:
ClusterA::> storage bridge show -wwn 200000XXXXXXXXXX
Is Monitor Managed Is Bridge
Bridge Symbolic Name Monitored Status By Vendor Model Bridge WWN Secure
------------------------ ------------- --------- ------- ------- ------ -------------------- ---------------- --------
ATTO_200000XXXXXXXXXX SW-ATTO-01 true ok in-band Atto FibreBridge 7500N 200000XXXXXXXXXX true
ATTO_FibreBridge7500N_23 - false - snmp Atto - 200000XXXXXXXXXX false
Note: The duplicate entry does not contain the WWN in the Bridge name
- The removal of the wrong entry is unsuccessful
Example:
ClusterA::> storage bridge remove -name ATTO_FibreBridge7500N_23
Error: command failed: "ATTO_FibreBridge7500N_23" has not been added for monitoring.