Skip to main content
NetApp Knowledge Base

Disk firmware update fails due to miscabling

Views:
270
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster FC
  • FAS/AFF
  • Storage disk firmware update
  • Brocade switch zoning/cabling

Issue

  • Customer reports error when trying to upgrade the disks
Problem Summary: FC-to-SAS bridge contacting problems:

Time                Node             Severity
Event
------------------- ---------------- ------------- ---------------------------
1/18/2022 13:36:08  netapp1       ERROR
dfu.badBridgeShelfConfig: Error contacting two peer FC-to-SAS bridges. Unable to download firmware to disk
FCswitch_B_2:8.126L01 [NETAPP   X342_TA14E1T2A10 NA04] S/N [xxxxxxxx].
1/18/2022 13:34:07  netapp1       ERROR
dfu.badBridgeShelfConfig: Error contacting two peer FC-to-SAS bridges. Unable to download firmware to disk FCswitch_B_2:8.126L01
[NETAPP   X342_SSKBE1T2A10 NA02] S/N [xxxxxxxx].
1/18/2022 13:33:42  netapp1       ERROR         disk.fw.downrevWarning: 4 disks
  • Output from sysconfig -a shows Single-path
  • Missing disk on 2 FC adapter ports on both clusters in 2 node Metro Cluster FC
slot 1: FC Host Adapter 1a (Emulex XE201 rev. 48, N-port, <UP>)
Board name:        111-xxxx
Serial Number:     FCxxxxxxxx
Firmware rev:      12.0.378.1
Host Port Id:      0x50100
FC Node Name:      2:xxx:xxxxxx:xxxxx83
FC Port Name:      1:000:xxxxxx:xxxxxx83
SFP Vendor:        EMULEX
SFP Part Number:   AFBR-57F5MZ-ELX
SFP Serial Number: ACxxxxxxxxxxxxx
SFP Capabilities:  4, 8 or 16 Gbit
Link Data Rate:    16 Gbit
Switch Port:       ?
slot 1: FC Host Adapter 1b (Emulex XE201 rev. 48, N-port, <UP>)
Board name:        111-xxxxx
Serial Number:     FCxxxxxxxx
Firmware rev:      12.0.378.1
Host Port Id:      0xxxxxx
FC Node Name:      2:xxx:xxxxxx:xxxxxx83
FC Port Name:      1:000:xxxxxx:xxxxxx83
SFP Vendor:        EMULEX
SFP Part Number:   AFBR-57F5MZ-ELX
SFP Serial Number: ACxxxxxxxxxxx
SFP Capabilities:  4, 8 or 16 Gbit
Link Data Rate:    16 Gbit
Switch Port:       ?

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.