Issue

  • DR mirroring is down in MetroCluster system:
Cluster_A::> metrocluster interconnect show
                          Mirror   Mirror
                  Partner Admin    Oper
Node Partner Name Type    Status   Status  Adapter Type   Status
---- ------------ ------- -------- ------- ------- ------ ------
ClusterA-01
     ClusterB-01
                  DR      enabled  online
                                           fcvi_device_0
                                                   FC-VI  Up
                                           fcvi_device_1
                                                   FC-VI  Down
2 entries were displayed.
  • The FCVI port is down on the node:

slot 2: FCVI Host Adapter 2b (QLogic 8324(2672) rev. 2, unknown)
             Physical link:       DOWN
             FC Node Name:        21:00:XX:XX:XX:XX:XX:XX
             Firmware rev:        8.01.141

  • The switch port connected to the FCVI port has no light:

switchshow        :
switchName:    MCC-SW4
switchType:    181.0
switchState:    Online  

Index Port Address  Media Speed   State      Proto
==================================================
   0   0   080000   id    16G      No_Light    FC  

  • There is no receive power on the SFP connected to the switch port:

MCC-SW4:admin> sfp show 0
=============
Port  0:
=============
Current:     7.496   mAmps
Voltage:     3254.4  mVolts
RX Power:    -inf    dBm (0.0  uW)
TX Power:    -1.4    dBm (732.5 uW)

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.