Issue

Following Installation of MetroCluster IP notes or during FC to IP transition, the HA, DR or AUX interconnect connectivity can be lost even though the physical connectivity is present and healthy.

  • The Mirror status will report as disabled and offline, even while the iWARP connections are up in metrocluster interconnect show:

Cluster1::> metrocluster interconnect show
  (metrocluster interconnect show)
                          Mirror   Mirror
                  Partner Admin    Oper
Node Partner Name Type    Status   Status  Adapter Type   Status
---- ------------ ------- -------- ------- ------- ------ ------
Node1A         Node2A HA enabled online
                                           e1a     iWARP  Up
                                           e1b     iWARP  Up
               Node1B DR disabled offline
                                           e1a     iWARP  Up
                                           e1b     iWARP  Up
               Node2B AUX disabled offline
                                           e1a     iWARP  Up
                                           e1b     iWARP  Up
Node2A         Node1A HA enabled online
                                           e1a     iWARP  Up
                                           e1b     iWARP  Up
               Node2B DR disabled offline
                                           e1a     iWARP  Up
                                           e1b     iWARP  Up
               Node1B AUX disabled offline
                                           e1a     iWARP  Up
                                           e1b     iWARP  Up

  • It is also possible that the Local HA will be offline because of the loss of NVRAM synchronization.  The eligibility to failover can be observed in storage failover show:
Cluster1::> storage failover show
                            Takeover
Node           Partner      Possible     State Description
-------------- ----------- --------     -------------------------------------------
NodeA1        NodeA2         true        Connected to NodeA2
NodeA2        NodeA1         true        Connected to NodeA1            
NodeA3        NodeA4         false       Waiting for NodeA4, Partial
                                         giveback, Takeover is not possible:
                                         Storage failover interconnect error,
                                         NVRAM log not synchronized, Disk
                                         inventory not exchanged
NodeA4        NodeA3         false       Waiting for NodeA3, Takeover
                                         is not possible: Storage failover
                                         interconnect error, NVRAM log not
                                         synchronized, Disk inventory not
                                         exchanged
                                       

::*> system ha interconnect status show

        Node: NodeA3
       Link Status:
     Link 0 Status: up
     Link 1 Status: up
IC RDMA Connection: down
  Is Link 0 Active: true
  Is Link 1 Active: true


 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.